Thread (15 messages) flat view 15 messages, 5 authors, 2018-07-09

[PATCH v4 6/6] arm64: dts: sdm845: Add tsens nodes

From: mka@chromium.org (Matthias Kaehlcke)
Date: 2018-07-09 16:01:51
Also in: linux-arm-msm, linux-devicetree, lkml

On Mon, Jul 09, 2018 at 04:56:51PM +0530, Amit Kucheria wrote:
On Wed, Jul 4, 2018 at 3:18 AM, Matthias Kaehlcke [off-list ref] wrote:
quoted
Hi,

On Mon, Jul 02, 2018 at 06:14:09PM +0530, Amit Kucheria wrote:
quoted
SDM845 has two tsens blocks, one with 13 sensors and the other with 8
sensors.

Signed-off-by: Amit Kucheria <redacted>
---
 arch/arm64/boot/dts/qcom/sdm845.dtsi | 16 ++++++++++++++++
 1 file changed, 16 insertions(+)
diff --git a/arch/arm64/boot/dts/qcom/sdm845.dtsi b/arch/arm64/boot/dts/qcom/sdm845.dtsi
index cdaabeb..edf8505 100644
--- a/arch/arm64/boot/dts/qcom/sdm845.dtsi
+++ b/arch/arm64/boot/dts/qcom/sdm845.dtsi
@@ -221,6 +221,22 @@
                      #interrupt-cells = <2>;
              };

+             tsens0: tsens at c222000 {
+                     compatible = "qcom,tsens-v2.4.0", "qcom,tsens-v2";
+                     reg = <0xc263000 0x1ff>, /* TM */
+                           <0xc222000 0x1ff>; /* SROT */
+                     #qcom,sensors = <13>;
+                     #thermal-sensor-cells = <1>;
+             };
+
+             tsens1: tsens at c223000 {
+                     compatible = "qcom,tsens-v2.4.0", "qcom,tsens-v2";
+                     reg = <0xc265000 0x1ff>, /* TM */
+                           <0xc223000 0x1ff>; /* SROT */
+                     #qcom,sensors = <8>;
+                     #thermal-sensor-cells = <1>;
+             };
+
              spmi_bus: spmi at c440000 {
                      compatible = "qcom,spmi-pmic-arb";
                      reg = <0xc440000 0x1100>,
I tested this series on an SDM845 board. Temperatures can be read from
the tsens0 sensors, however for tsens1 sensors I get:

cat temp
cat: temp: No data available

TRDY_READY_BIT set when reading TRDY_OFFSET in get_temp_tsens_v2().
Unfortunately I currently have no documentation of the registers or the
thermal sensors in general and couldn't investigate further.

Any idea what could be the problem?
Strangely enough, I'm seeing this now after rebuilding my integration
branch to test some other bits.

I've sent another version with this patch removed while I investigate
this. Could you check if you're able to read all 8 sensors with v5?
With v6 all sensors can be read, thanks!
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help