Motorola Droid 4 progress, power consumption
From: Pavel Machek <hidden>
Date: 2018-05-03 09:06:15
Also in:
linux-omap, lkml
Hi!
quoted
Anyway, >5.5hours of standby with screen off, GSM on is already usable.Just to rub that in, you do mean GSM usable for voice calls and SMS with your unicsy_demo with mainline kernel plus the pending LCD related patches, right? :)quoted
This is the core of code I'm using. https://github.com/pavelmachek/unicsy_demo Battery graphs are attached. I'm not sure if the battery was really close to empty at that point -- voltage curve should have different shape if that was the case.Cool. BTW, the value for POWER_SUPPLY_POWER_AVG should be quite accurate for the whole device power consumption. It comes from the shunt resistor measured by the PMIC. Sorry I don't remember how often it needs to be polled but I'm guessing polling it once a minute or so should be plenty.
I'd like current_avg more, but if I cat it manually, it changes on order of seconds, and quite significantly... which suggest shorter polling interval would be needed. user at devuan:/sys/class/power_supply/battery$ date; cat current_now current_avg Thu May 3 09:33:05 CEST 2018 -71000 -218408 user at devuan:/sys/class/power_supply/battery$ date; cat current_now current_avg Thu May 3 09:33:06 CEST 2018 -61000 -200238 user at devuan:/sys/class/power_supply/battery$ date; cat current_now current_avg Thu May 3 09:33:06 CEST 2018 -51000 -209879 user at devuan:/sys/class/power_supply/battery$ date; cat current_now current_avg Thu May 3 09:33:07 CEST 2018 -56000 -72308 user at devuan:/sys/class/power_supply/battery$ date; cat current_now current_avg Thu May 3 09:33:08 CEST 2018 -37000 -211362
Hmm oh and the POWER_SUPPLY_CHARGE_COUNTER value should be monitored by your libbattery and it's low value and high value should be saved to a file. Low should be saved when we get the battery low interrupt and battery state changes to POWER_SUPPLY_CAPACITY_LEVEL_CRITICAL. High value should be saved on POWER_SUPPLY_CAPACITY_LEVEL_FULL. Then when you know the high value and low value, you can calculate the remaining capacity based on the current value and POWER_SUPPLY_POWER_AVG.
I'll look into that... but probably will do experiments with python, first. Best regards, Pavel -- (english) http://www.livejournal.com/~pavelmachek (cesky, pictures) http://atrey.karlin.mff.cuni.cz/~pavel/picture/horses/blog.html -------------- next part -------------- A non-text attachment was scrubbed... Name: signature.asc Type: application/pgp-signature Size: 181 bytes Desc: Digital signature URL: <http://lists.infradead.org/pipermail/linux-arm-kernel/attachments/20180503/5bccc8c0/attachment.sig>