Thread (3 messages) flat view 3 messages, 3 authors, 2017-09-08

[PATCH 1/8] ARM: dts: sun6i: Fix endpoint IDs in second display pipeline

From: Chen-Yu Tsai <hidden>
Date: 2017-09-08 13:38:23
Also in: dri-devel, linux-devicetree

On Fri, Sep 8, 2017 at 9:29 PM, Maxime Ripard
[off-list ref] wrote:
Hi,

On Fri, Sep 08, 2017 at 03:50:09PM +0800, Chen-Yu Tsai wrote:
quoted
When the second display pipeline device nodes for the A31/A31s were
added, it was not known that the TCONs could (through either DRCs)
select either backend as their input. Thus in the endpoints connecting
these components together, the endpoint IDs were set to 0, while in
fact they should have been set to 1.

Fixes: 9a26882a7378 ("ARM: dts: sun6i: Add second display pipeline device
                    nodes")
Signed-off-by: Chen-Yu Tsai <redacted>
Should we CC stable on this one?
It wouldn't matter for old kernels, but I suppose we should get it right
everywhere, so we should probably CC stable. Also I forgot to mention
that this patch should go in -fixes, while the rest can go in -next.

Thanks
ChenYu
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help