On Thursday 26 January 2017 10:26 PM, Grygorii Strashko wrote:
On 01/23/2017 11:00 AM, Bartosz Golaszewski wrote:
quoted
The ahci-da850 SATA driver is now capable of retrieving clocks by
con_id. Add the connection id for the sysclk2-derived SATA clock.
Signed-off-by: Bartosz Golaszewski <redacted>
---
arch/arm/mach-davinci/da850.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/arch/arm/mach-davinci/da850.c b/arch/arm/mach-davinci/da850.c
index 1d873d1..dbf1daa 100644
--- a/arch/arm/mach-davinci/da850.c
+++ b/arch/arm/mach-davinci/da850.c
@@ -571,7 +571,7 @@ static struct clk_lookup da850_clks[] = {
CLK("spi_davinci.0", NULL, &spi0_clk),
CLK("spi_davinci.1", NULL, &spi1_clk),
CLK("vpif", NULL, &vpif_clk),
- CLK("ahci_da850", NULL, &sata_clk),
+ CLK("ahci_da850", "sata", &sata_clk),
I'm worry a bit - wouldn't this cause future problems with PM runtime
(if it will be the case)?
If this is functional clock - shouldn't it be "fck" to
follow PM domain con_id list for davinci? (arch/arm/mach-davinci/pm_domain.c)
I agree with Grygorii. Calling this clock "fck" will make it easy to
convert the DA850 AHCI driver to use pm_runtime at a future date (no
mach-davinci changes should be needed).
Sorry about not spotting this earlier.
Thanks,
Sekhar