Hello Laxman,
On 06/16/2016 09:23 AM, Laxman Dewangan wrote:
Maxim has used the same clock IP on multiple PMICs like MAX77686,
MAX77802, MAX77620. Only differences are the number of clocks
from these PMICs like MAX77686 has 3 clocks output, MAX776802 have
two clock output and MAX77620 has one clock output.
Add clock binding details and DT example for the MAX77620.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
CC: Krzysztof Kozlowski <redacted>
CC: Javier Martinez Canillas <javier@dowhile0.org>
---
Reviewed-by: Javier Martinez Canillas <redacted>
Best regards,
--
Javier Martinez Canillas
Open Source Group
Samsung Research America