Hi Baptiste,
quoted
I couldn't see a reset function for AMBA devices.
Is there anyway to write reset function for it? I have no experience with
AMBA devices.
To my knowledge only the PL330 DMA controller (drivers/dma/pl330.c) was
passthrough'ed at some point, rather for development purpose than
production purpose. This was done by Virtual Open Systems (ask Baptiste
for more details). But I don't think this is really used.
Are you OK with requiring reset driver for AMBA devices too? The PL330
driver won't work until a reset driver is submitted for it.
quoted
Would you include a reset needed flag and just not require it for AMBA?
(I honestly don't like this idea)
I think the requirement also makes sense for AMBA.
Maybe an option would be to add a module parameter that would allow to
use the vfio platform/amba driver without reset module (with explicit
opt-in from the user). Maybe this can be done later on.
I can see this flag useful for testing purposes but it should not be used in
production.
How about I add a module parameter which is not set by default? When set,
I don't perform the reset requirement check.
FYI I will not have access to my mailbox until the end of the week.
OK, no rush.
Best Regards
Eric
--
Sinan Kaya
Qualcomm Technologies, Inc. on behalf of Qualcomm Innovation Center, Inc.
Qualcomm Innovation Center, Inc. is a member of Code Aurora Forum, a Linux Foundation Collaborative Project