On Mon, Feb 1, 2016 at 11:48 PM, Sebastian Hesselbarth
[off-list ref] wrote:
When assigning mpp settings from static mpp modes to mpp groups,
we do not want any groups that have no supported setting for a
specific Kirkwood variant. However, when there is at least a
single supported setting, we need to assign the number of all
settings in this mode to grp->num_settings as we are reusing
the static modes table.
Fixes: 0581b16b1840 ("pinctrl: mvebu: complain about missing group after checking variant")
Reported-by: Aaro Koskinen <aaro.koskinen@iki.fi>
Signed-off-by: Sebastian Hesselbarth <sebastian.hesselbarth@gmail.com>
--
Changelog:
v1->v2:
- Chose a less intrusive fix by adding supp_settings variable
instead of looping over the settings twice.
Patch applied with Aaro's Test tag.
Yours,