mtd: pxa3xx_nand: issue with command time out

flat view

From: ezequiel@vanguardiasur.com.ar (Ezequiel Garcia)
Date: 2016-01-26 13:03:57

On 25 January 2016 at 17:48, Robert Jarzmik [off-list ref] wrote:
Brian Norris [off-list ref] writes:
quoted
Hi Robert,

On Sun, Jan 17, 2016 at 12:53:06AM +0100, Robert Jarzmik wrote:
commit 24542257a3b987025d4b998ec2d15e556c98ad3f
Author: Robert Jarzmik [off-list ref]
Date:   Fri Feb 20 19:36:43 2015 +0100

    mtd: pxa3xx-nand: handle PIO in threaded interrupt


And now I'm wondering: when does the completion get triggered? i.e.:

      complete(&info->cmd_complete);
quoted
It seems to me like you've short-circuited some of the IRQ handling
code, so that the threaded handler is buggy. AIUI, if the completion
event ever happens, it's actually happening *before* the full (threaded)
handler is actually finished, since it occurs in pxa3xx_nand_irq(),
before pxa3xx_nand_irq_thread() ever runs. Now, I'm not sure if that
causes a real problem in practice, since you used IRQF_ONESHOT, but I
would think that's also suspect.
I think you're very right, this "goto NORMAL_IRQ_EXIT" creates a
short-cirtcuit. That makes me think that I should :
 - add
static void pxa3xx_nand_data_finished(struct pxa3xx_nand_info *info)
{
        unsigned int done;

        cmd_done = info->cs ? NDSR_CS1_CMDD : NDSR_CS0_CMDD;
        nand_writel(info, NDSR, cmd_done);
        complete(&inf0->cmd_complete);
}

 - in pxa3xx_nand_irq_thread(), I should add at the end:
        pxa3xx_nand_data_finished(info);

 - in pxa3xx_nand_data_dma_irq(), I should add at the end:
        pxa3xx_nand_data_finished(info);

Ezequiel, would you have a look at that code snippet and tell me if I'm missing
something in the driver's structure ?
Although it seems Brian is right, I'm not so sure about it. As far as
I can recall, the IRQ sequence is (please correct me if I'm wrong!):

1. Write command request (WRCMDREQ), the IRQ handler writes the command.
2. Read/write data request (RDDREQ | WRDREQ). The IRQ handler fires
the threaded handler, which does data transfer.
3. Command done IRQ (CMDD), the IRQ handler completes the completion.

I don't think data request and command done can be found
simultaneously, so I don't think this is a real issue. Ideas?

Regarding the fixed proposed up there, it seems wrong: the completion
should be completed only after a command done IRQ is found, and not as
the result of data transfer being finished.
-- 
Ezequiel Garc?a, VanguardiaSur
www.vanguardiasur.com.ar