Thread (1 message) 1 message, 1 author, 2015-12-22
DORMANTno replies

[PATCH 2/2] ARM: mvebu: use regulator-boot-on on Armada 388 GP

From: Gregory CLEMENT <hidden>
Date: 2015-12-22 12:23:20

Hi Thomas,
 
 On lun., d?c. 21 2015, Thomas Petazzoni [off-list ref] wrote:
Really, what we meant by regulator-always-on is that the regulators
are already turned on by the bootloader, for which regulator-boot-on
is a better description.
What happened if the bootloader do not turn the regulator on?
I fear that in this case the regulator won't be turned on at all.
quoted hunk
A net advantage of using regulator-boot-on is that the regulator is
not touched at boot time by the kernel, which avoids having the hard
drives spinning down and then up again, taking several (~5) seconds of
additional boot time.

In addition, there is no need to have such properties on the child
regulators used for SATA. Having it on the parent regulator that
really controls the GPIO is sufficient.

Signed-off-by: Thomas Petazzoni <redacted>
---
 arch/arm/boot/dts/armada-388-gp.dts | 24 ++++++++----------------
 1 file changed, 8 insertions(+), 16 deletions(-)
diff --git a/arch/arm/boot/dts/armada-388-gp.dts b/arch/arm/boot/dts/armada-388-gp.dts
index d8dab0f..1ef6cc6 100644
quoted hunk
 
@@ -309,7 +309,7 @@
 		regulator-min-microvolt = <5000000>;
 		regulator-max-microvolt = <5000000>;
 		enable-active-high;
-		regulator-always-on;
+		regulator-boot-on;
 		gpio = <&expander0 4 GPIO_ACTIVE_HIGH>;
 	};
This node had been removed by a patch you sent few days ago:
"ARM: mvebu: remove duplicated regulator definition in Armada 388 GP"

Thanks,

Gregory

-- 
Gregory Clement, Free Electrons
Kernel, drivers, real-time and embedded Linux
development, consulting, training and support.
http://free-electrons.com