Thread (21 messages) 21 messages, 3 authors, 2015-11-03

[PATCH v2 2/5] mfd: ts4800-syscon: add driver for TS-4800 syscon

From: Damien Riegel <hidden>
Date: 2015-11-03 14:36:44
Also in: linux-watchdog, lkml

On Tue, Nov 03, 2015 at 11:48:38AM +0100, Arnd Bergmann wrote:
On Tuesday 03 November 2015 10:12:17 Lee Jones wrote:
quoted
quoted
I think a 'buswidth=<16>;' property in addition to 'compatible="syscon"'
is more in line with what other subsystems do.
Perfect.
Just to clarify: I just checked the other DT bindings and it should
actually be "bus-width", not "buswidth".
Actually, I need the set the three following values of regmap_config:
reg_bits, reg_stride, and val_bits.

I had the following mapping in mind:
@@ -69,6 +70,18 @@ static struct syscon *of_syscon_register(struct device_node *np)
         else if (of_property_read_bool(np, "little-endian"))
                syscon_config.val_format_endian = REGMAP_ENDIAN_LITTLE;
 
+       ret = of_property_read_u32(np, "reg-bits", &val);
+       if (!ret)
+               syscon_config.reg_bits = val;
+
+       ret = of_property_read_u32(np, "val-bits", &val);
+       if (!ret)
+               syscon_config.val_bits = val;
+
+       ret = of_property_read_u32(np, "reg-stride", &val);
+       if (!ret)
+               syscon_config.reg_stride = val;
+
        regmap = regmap_init_mmio(NULL, base, &syscon_config);
        if (IS_ERR(regmap)) {
                pr_err("regmap init failed\n");

Would you prefer other property names, like "reg-bus-width",
"val-bus-width", and "reg-stride"? Should I prefix them with "syscon,"?


	Damien
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree