Thread (3 messages) 3 messages, 2 authors, 2015-09-06

[PATCH 1/1] ARM: imx35: Do not call mxc_timer_init twice when booting with DT

From: Alexander Stein <hidden>
Date: 2015-08-26 11:10:03
Also in: linux-clk

On Tuesday 11 August 2015 09:18:22, Alexander Stein wrote:
mxc_timer_init must not be called from within mx35_clocks_init_dt. It will
eventually be called by imx31_timer_init_dt
(drivers/clocksources/timer-imx-gpt.c).
This arranges the initialization code similar to clk-imx27.c
Any feedback on this?