Hello MyungJoo,
On 08/03/2015 06:58 AM, MyungJoo Ham wrote:
quoted
Hello Myungjoo,
On 07/23/2015 10:30 AM, Javier Martinez Canillas wrote:
quoted
Hello Chanwoo,
On 07/23/2015 10:19 AM, Chanwoo Choi wrote:
quoted
Hi Javier,
On 07/13/2015 03:58 PM, Javier Martinez Canillas wrote:
quoted
The exynos-ppmu driver is only a clock consumer and not a clock
provider but its Device Tree binding listed #clock-cells as an
optional property.
Signed-off-by: Javier Martinez Canillas <redacted>
[]
quoted
quoted
quoted
quoted
Example1 : PPMU nodes in exynos3250.dtsi are listed below.
Reviewed-by: Chanwoo Choi <cw00.choi@samsung.com>
+ Devfreq maintainer (Myungjoo Ham)
Thanks for the review and for cc'ing Myungjoo. The get_maintainer.pl script
didn't tell me that so I think Documentation/devicetree/bindings/devfreq/
sub-dir should be added to the DEVICE FREQUENCY (DEVFREQ) entry in the
MAINTAINERS file.
quoted
I think that this patch will be more appropriate on devfreq git tree
than linux-samsung git tree.
Agreed.
Any comments about this patch?
Nope. It's applied.
Thanks.
Great, thanks a lot.
MyungJoo
Best regards,
--
Javier Martinez Canillas
Open Source Group
Samsung Research America