Thread (34 messages) 34 messages, 6 authors, 2015-06-15

[PATCH 2/5] clk: mediatek: mt8173: Fix enabling of critical clocks

From: s.hauer@pengutronix.de (Sascha Hauer)
Date: 2015-05-26 07:46:26
Also in: linux-devicetree, linux-mediatek, lkml

On Thu, May 21, 2015 at 03:12:53PM +0800, James Liao wrote:
quoted hunk ↗ jump to hunk
From: Sascha Hauer <s.hauer@pengutronix.de>

On the MT8173 the clocks are provided by different units. To enable
the critical clocks we must be sure that all parent clocks are already
registered, otherwise the parents of the critical clocks end up being
unused and get disabled later. To find a place where all parents are
registered we try each time after we've registered some clocks if
all known providers are present now and only then we enable the critical
clocks

Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
Signed-off-by: James Liao <redacted>
---
 drivers/clk/mediatek/clk-mt8173.c | 24 +++++++++++++++++++-----
 1 file changed, 19 insertions(+), 5 deletions(-)
diff --git a/drivers/clk/mediatek/clk-mt8173.c b/drivers/clk/mediatek/clk-mt8173.c
index 4b9e04c..eb175ac 100644
--- a/drivers/clk/mediatek/clk-mt8173.c
+++ b/drivers/clk/mediatek/clk-mt8173.c
@@ -700,6 +700,20 @@ static const struct mtk_composite peri_clks[] __initconst = {
 	MUX(CLK_PERI_UART3_SEL, "uart3_ck_sel", uart_ck_sel_parents, 0x40c, 3, 1),
 };
 
+static struct clk_onecell_data *mt8173_top_clk_data;
+static struct clk_onecell_data *mt8173_pll_clk_data;
+
+static void mtk_clk_enable_critical(void)
+{
+	if (!mt8173_top_clk_data || !mt8173_pll_clk_data)
+		return;
+
+	clk_prepare_enable(mt8173_top_clk_data->clks[CLK_TOP_MEM_SEL]);
+	clk_prepare_enable(mt8173_top_clk_data->clks[CLK_TOP_DDRPHYCFG_SEL]);
+	clk_prepare_enable(mt8173_top_clk_data->clks[CLK_TOP_CCI400_SEL]);
+	clk_prepare_enable(mt8173_top_clk_data->clks[CLK_TOP_RTC_SEL]);
Is CLK_TOP_RTC_SEL really a critical clock?

Sascha


-- 
Pengutronix e.K.                           |                             |
Industrial Linux Solutions                 | http://www.pengutronix.de/  |
Peiner Str. 6-8, 31137 Hildesheim, Germany | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree