On 03/06/15 15:41, Stephen Boyd wrote:
The ahbix clock can never be turned off in practice. To change the
rates we need to switch the mux off the M/N counter to an always on
source (XO), reprogram the M/N counter to get the rate we want and
finally switch back to the M/N counter. Add a new ops structure
for this type of clock so that we can set the rate properly.
Fixes: c99e515a92e9 "clk: qcom: Add IPQ806X LPASS clock controller (LCC) driver"
Cc: Kenneth Westfield <redacted>
Signed-off-by: Stephen Boyd <redacted>
---
Applied to clk-next
--
Qualcomm Innovation Center, Inc. is a member of Code Aurora Forum,