On Wed, Feb 25, 2015 at 02:32:07PM -0800, Stephen Boyd wrote:
The ahbix clock can never be turned off. To switch the rates we
need to switch the mux off the M/N counter to an always on source
(XO), reprogram the M/N counter to get the rate we want and
finally switch back to the M/N counter. Add a new ops structure
for this type of clock so that we can set the rate properly.
Fixes: c99e515a92e9 "clk: qcom: Add IPQ806X LPASS clock controller (LCC) driver"
Cc: Kenneth Westfield <redacted>
Signed-off-by: Stephen Boyd <redacted>
---
drivers/clk/qcom/clk-rcg.c | 30 ++++++++++++++++++++++++++++++
drivers/clk/qcom/clk-rcg.h | 1 +
drivers/clk/qcom/lcc-ipq806x.c | 5 +----
3 files changed, 32 insertions(+), 4 deletions(-)
Verified soundcard instantiation on the ipq806x SOC with max98357a codec.
Tested-by: Kenneth Westfield <redacted>
--
Kenneth Westfield
Qualcomm Innovation Center, Inc.
The Qualcomm Innovation Center, Inc. is a member of the Code Aurora Forum,
a Linux Foundation Collaborative Project