[RFC PATCH v3] edac: synps: Added EDAC support for zynq ddr ecc controller

From: bp@alien8.de (Borislav Petkov)
Date: 2014-07-31 11:33:31
Also in: linux-devicetree, lkml

On Wed, Jul 30, 2014 at 03:41:47PM +0000, Punnaiah Choudary Kalluri wrote:
quoted
So you're telling me that you want one edac driver for *two* memory
controllers which can be present on a single system *at* *the* *same*
*time*? Is that it?
Yes.
Oh, this'll be fun. :-P
quoted
How exactly is that topology supposed to look like, work, etc, etc? What
kind of error reporting do you imagine you want to do with EDAC?
Zynq (All programmable SOC) contains a dual core ARM cortex A9 based processing
System(PS) and Xilinx programmable logic(PL) in a single device.

Assume the application is a broadcast camera. The design for this system use PS as
Control plane and use PL as data plane for processing the video data. So, the design 
may have two different memory controllers one in PS and another one in PL.   
PS is running with Linux OS and PL doesn't have the OS and it is  controlled by the 
OS running on PS.
Ok.
 Now the requirement is to develop a monitoring system for all the
hardware failures Including ddr ecc errors. Since the broadcast camera
involves more data processing and DDR memory access, there is a high
probability of getting ddr ecc errors over the period.
So you're saying the camera has memory with ECC? People really pay
attention on getting error free video frames? :-)

Or this is just an example? You're saying the PL will need ECC for some
applications?
So, the user should be intimated with these errors when they occur and if the error rate
 is high, then the user can consider the preventive methods. Without this error reporting
mechanism it is difficult to debug the issues like memory corruption, kernel oops which
 may occur due to ddr ecc failures.

Since, the memory controllers are different, it need two edac drivers for reporting the ecc 
errors and also maintaining the statistics of that particular memory controller. With the current
framework, there is a chance that both the drivers get mc_num as zero and malfunction. 
Assume the code for the two drivers looks like below

Driver 1:
	mci = edac_mc_alloc(0, ARRAY_SIZE(layers), layers,
			    sizeof(struct  ctrl1_drvdata));

Driver 2:
	mci = edac_mc_alloc(0, ARRAY_SIZE(layers), layers,
			    sizeof(struct ctrl2_drvdata));

Issue:
  Since driver is providing the mc_num to framework, now there is chance that only one device active as
 both the drivers claiming the same number.

Solution 1:
 Keep two drivers in single file and use static global variable for tracking the mc_num. This solution looks
good but the drivers may not be generic as these driver would be in a zynq_edac.c file. So others may not
reuse these drivers
Ok, I think I know what you mean. And this architecture works just fine.
On x86 we have one EDAC instance per memory controller so on a multinode
machine with multiple memory controllers, we do edac_mc_alloc() per
memory controller.

For examples, see amd64_edac::init_one_instance() and sb_edac should
have this too. So you basically have a local array of instances which
you allocate and setup.

If someone wants to reuse the driver, then we can talk about this later,
when the time comes.

For now I think you should put both PS and PL stuff in one file,
zynq_edac or so.

Any issues with this design?

-- 
Regards/Gruss,
    Boris.