[PATCH v3 4/4] can: flexcan: add vf610 support for FlexCAN
From: stefan@agner.ch (Stefan Agner)
Date: 2014-07-25 10:50:39
Also in:
lkml
Am 2014-07-16 08:43, schrieb Stefan Agner:
Am 2014-07-15 16:24, schrieb Marc Kleine-Budde: <snip>quoted
quoted
@@ -150,18 +171,20 @@ * FLEXCAN hardware feature flags * * Below is some version info we got: - * SOC Version IP-Version Glitch- [TR]WRN_INT - * Filter? connected? - * MX25 FlexCAN2 03.00.00.00 no no - * MX28 FlexCAN2 03.00.04.00 yes yes - * MX35 FlexCAN2 03.00.00.00 no no - * MX53 FlexCAN2 03.00.00.00 yes no - * MX6s FlexCAN3 10.00.12.00 yes yes + * SOC Version IP-Version Glitch- [TR]WRN_INT Memory err + * Filter? connected? detection + * MX25 FlexCAN2 03.00.00.00 no no no + * MX28 FlexCAN2 03.00.04.00 yes yes no + * MX35 FlexCAN2 03.00.00.00 no no no + * MX53 FlexCAN2 03.00.00.00 yes no no + * MX6s FlexCAN3 10.00.12.00 yes yes no + * VF610 FlexCAN3 ? no no yes^^ ^^ Can you check the datasheet if the flexcan core has a "Glitch Filter Width Register (FLEXCANx_GFWR)"There is no such register called GFWR/Glitch Filter or similar.quoted
Can you check if the core generates a warning interrupt with the current setup, if you don't switch on bus error reporting? This means internally the [TR]WRN_INT is connected and works as specified.Ok, so I disabled TWRNMSK (Bit 11) in the control register and printed out the error and status register (ESR1), this is what I get: [ 191.285295] flexcan_irq, esr=00040080 [ 191.288996] flexcan_irq, ctrl=17092051 Bit 17 (TWRNINT) is not set while TWRNMSK is disabled. Hence [TR]WRN_INT is not connected?
Ping. Anything open/to do from my side? -- Stefan