[linux-pm] [RFC PATCH 2/5] thermal: cpu_cooling: Add notifications support for the clients

From: amit daniel kachhap <hidden>
Date: 2014-05-19 08:59:21
Also in: linux-acpi, lkml

On Fri, May 16, 2014 at 12:15 AM, Eduardo Valentin [off-list ref] wrote:
Hello Amit,


On Thu, May 08, 2014 at 08:07:57PM +0530, Amit Daniel Kachhap wrote:
quoted
This patch adds notification support for those clients of cpu_cooling
APIs which may want to do something interesting after receiving these
cpu_cooling events. The notifier structure passed is of both Set/Get type.
The notfications events can be of type,
1. CPU_COOLING_SET_STATE_PRE
2. CPU_COOLING_SET_STATE_POST
3. CPU_COOLING_GET_CUR_STATE
4. CPU_COOLING_GET_MAX_STATE
What do you think about expanding this feature to all cooling devices?

I mean, why should we restrict to cpu(freq) cooling?
nice suggestion. Sure will check its feasibility.
The clock cooling device I posted (and that I plan to merge soon) should
also benefit of this infrastructure. The clock cooling is for the
context of other processing units, that do not benefit of cpufreq.
ok let me check them.
quoted
The advantages of these notfications is to differentiate between different
P states in the cpufreq table and the cooling states. The clients of these
events may group few P states into 1 cooling states. Also some more cooling
states can be enabled when the maximum of P state is reached. Post notifications
can be used for those cases.

Signed-off-by: Amit Daniel Kachhap <redacted>
---
 drivers/thermal/cpu_cooling.c |   99 +++++++++++++++++++++++++++++++++++++++-
 include/linux/cpu_cooling.h   |   55 +++++++++++++++++++++++
 2 files changed, 151 insertions(+), 3 deletions(-)
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index 21f44d4..e2aeb36 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -50,6 +50,7 @@ struct cpufreq_cooling_device {
      unsigned int cpufreq_state;
      unsigned int cpufreq_val;
      struct cpumask allowed_cpus;
+     struct cpufreq_cooling_status request_status;
      struct list_head node;
 };
 static DEFINE_IDR(cpufreq_idr);
@@ -59,6 +60,8 @@ static DEFINE_MUTEX(cooling_cpufreq_lock);
 #define NOTIFY_INVALID NULL
 static struct cpufreq_cooling_device *notify_device;

+/* Notfier list to validates/updates the cpufreq cooling states */
+static BLOCKING_NOTIFIER_HEAD(cpufreq_cooling_state_notifier_list);
 /* A list to hold all the cpufreq cooling devices registered */
 static LIST_HEAD(cpufreq_cooling_list);
@@ -266,6 +269,21 @@ static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level)
      return freq;
 }

+static int
+cpufreq_cooling_notify_states(struct cpufreq_cooling_status *request,
+                     enum cpu_cooling_state_ops op)
+{
+     /* Invoke the notifiers which have registered for this state change */
+     if (op == CPU_COOLING_SET_STATE_PRE ||
+             op == CPU_COOLING_SET_STATE_POST ||
+             op == CPU_COOLING_GET_MAX_STATE ||
+             op == CPU_COOLING_GET_CUR_STATE) {
+             blocking_notifier_call_chain(
+                     &cpufreq_cooling_state_notifier_list, op, request);
+     }
+     return 0;
+}
+
 /**
  * cpufreq_apply_cooling - function to apply frequency clipping.
  * @cpufreq_device: cpufreq_cooling_device pointer containing frequency
@@ -285,9 +303,18 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
      struct cpumask *mask = &cpufreq_device->allowed_cpus;
      unsigned int cpu = cpumask_any(mask);

+     cpufreq_device->request_status.cur_state =
+                                             cpufreq_device->cpufreq_state;
+     cpufreq_device->request_status.new_state = cooling_state;
+
+     cpufreq_cooling_notify_states(&cpufreq_device->request_status,
+                                     CPU_COOLING_SET_STATE_PRE);
+
Can a listener block/abort/postpone a state transition?
quoted
+     cooling_state = cpufreq_device->request_status.new_state;
So you are proposing listeners can have control on target cpufreq state,
right? Or did I get it wrong?

I think we should have this better documented. Besides, if that is the
case, what happens if we have several listeners?
quoted
      /* Check if the old cooling action is same as new cooling action */
-     if (cpufreq_device->cpufreq_state == cooling_state)
+     if (cpufreq_device->cpufreq_state ==
+                             cpufreq_device->request_status.new_state)
              return 0;

      clip_freq = get_cpu_frequency(cpu, cooling_state);
@@ -304,7 +331,8 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
      }

      notify_device = NOTIFY_INVALID;
-
+     cpufreq_cooling_notify_states(&cpufreq_device->request_status,
+                                     CPU_COOLING_SET_STATE_POST);
      return 0;
 }
@@ -383,6 +411,11 @@ static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
      if (count > 0)
              *state = count;

+     cpufreq_device->request_status.max_state = count;
+     cpufreq_cooling_notify_states(&cpufreq_device->request_status,
+                                     CPU_COOLING_GET_MAX_STATE);
+     *state = cpufreq_device->request_status.max_state;
+
same question here, who determines the priorities when several listeners
are present in the system?
quoted
      return ret;
 }
@@ -410,8 +443,12 @@ static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
              /* Cooling device pointer not found */
              return -EINVAL;
      }
+     cpufreq_device->request_status.cur_state =
+                                             cpufreq_device->cpufreq_state;
+     cpufreq_cooling_notify_states(&cpufreq_device->request_status,
+                                     CPU_COOLING_GET_CUR_STATE);
ditto.
quoted
-     *state = cpufreq_device->cpufreq_state;
+     *state = cpufreq_device->request_status.cur_state;

      return 0;
 }
@@ -520,6 +557,7 @@ __cpufreq_cooling_register(struct device_node *np,
      }
      cpufreq_dev->cool_dev = cool_dev;
      cpufreq_dev->cpufreq_state = 0;
+     cpufreq_dev->request_status.devdata = devdata;
      mutex_lock(&cooling_cpufreq_lock);

      /* Register the notifier for first cpufreq cooling device */
@@ -614,3 +652,58 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
      kfree(cpufreq_dev);
 }
 EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);
+
+/**
+ * cpufreq_cooling_register_notifier - register a driver with cpufreq cooling.
+ * @nb:      notifier function to register.
+ * @list: CPU_COOLING_STATE_NOTIFIER type.
+ *
+ * Add a driver to receive cpufreq cooling notifications like current state,
+ * max state and set state. The drivers after reading the events can perform
+ * some mapping between the P states and cooling states like grouping some P
+ * states into 1 cooling state.
+ *
+ * Return: 0 (success)
+ */
+int cpufreq_cooling_register_notifier(struct notifier_block *nb,
+                                     unsigned int list)
+{
+     int ret = 0;
+     switch (list) {
+     case CPU_COOLING_STATE_NOTIFIER:
+             ret = blocking_notifier_chain_register(
+                             &cpufreq_cooling_state_notifier_list, nb);
+             break;
+     default:
+             ret = -EINVAL;
+     }
+     return ret;
+}
+EXPORT_SYMBOL_GPL(cpufreq_cooling_register_notifier);
+
+/**
+ * cpufreq_cooling_unregister_notifier - unregisters a driver with cpufreq
+ * cooling.
+ * @nb:      notifier function to unregister.
+ * @list: CPU_COOLING_STATE_NOTIFIER type.
+ *
+ * Removes a driver to receive further cpufreq cooling notifications.
+ *
+ * Return: 0 (success)
+ */
+int cpufreq_cooling_unregister_notifier(struct notifier_block *nb,
+                                     unsigned int list)
+{
+     int ret = 0;
+     switch (list) {
+     case CPU_COOLING_STATE_NOTIFIER:
+             ret = blocking_notifier_chain_unregister(
+                             &cpufreq_cooling_state_notifier_list, nb);
+             break;
+     default:
+             ret = -EINVAL;
+     }
+
+     return ret;
+}
+EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister_notifier);
The exported symbols must be documented under Documentation/ too.
quoted
diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h
index aaef7d8..f786935 100644
--- a/include/linux/cpu_cooling.h
+++ b/include/linux/cpu_cooling.h
@@ -28,6 +28,22 @@
 #include <linux/thermal.h>
 #include <linux/cpumask.h>

+#define CPU_COOLING_STATE_NOTIFIER   (0)
+
+enum cpu_cooling_state_ops {
+     CPU_COOLING_SET_STATE_PRE,
+     CPU_COOLING_SET_STATE_POST,
+     CPU_COOLING_GET_CUR_STATE,
+     CPU_COOLING_GET_MAX_STATE,
+};
+
+struct cpufreq_cooling_status {
+     unsigned long cur_state;
+     unsigned long new_state;
+     unsigned long max_state;
+     void *devdata;
+};
+
 #ifdef CONFIG_CPU_THERMAL
 /**
  * cpufreq_cooling_register - function to create cpufreq cooling device.
@@ -62,6 +78,34 @@ of_cpufreq_cooling_register(struct device_node *np,
 void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);

 unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq);
+
+/**
+ * cpufreq_cooling_register_notifier - register a driver with cpufreq cooling.
+ * @nb:      notifier function to register.
+ * @list: CPU_COOLING_STATE_NOTIFIER type.
+ *
+ * Add a driver to receive cpufreq cooling notifications like current state,
+ * max state and set state. The drivers after reading the events can perform
+ * some mapping between the P states and cooling states like grouping some P
+ * states into 1 cooling state.
+ *
+ * Return: 0 (success)
+ */
+int cpufreq_cooling_register_notifier(struct notifier_block *nb,
+                                     unsigned int list);
+
+/**
+ * cpufreq_cooling_unregister_notifier - unregisters a driver with cpufreq
+ * cooling.
+ * @nb:      notifier function to unregister.
+ * @list: CPU_COOLING_STATE_NOTIFIER type.
+ *
+ * Removes a driver to receive further cpufreq cooling notifications.
+ *
+ * Return: 0 (success)
+ */
+int cpufreq_cooling_unregister_notifier(struct notifier_block *nb,
+                                     unsigned int list);
 #else /* !CONFIG_CPU_THERMAL */
 static inline struct thermal_cooling_device *
 cpufreq_cooling_register(const struct cpumask *clip_cpus, void *devdata)
@@ -84,6 +128,17 @@ unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
 {
      return THERMAL_CSTATE_INVALID;
 }
+static inline int
+cpufreq_cooling_register_notifier(struct notifier_block *nb, unsigned int list)
+{
+     return 0;
+}
+static inline int
+cpufreq_cooling_unregister_notifier(struct notifier_block *nb,
+                                     unsigned int list)
+{
+     return 0;
+}
 #endif       /* CONFIG_CPU_THERMAL */

 #endif /* __CPU_COOLING_H__ */
--
1.7.1

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo at vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help