Am Mittwoch, den 05.03.2014, 15:00 +0800 schrieb Shawn Guo:
On Fri, Feb 28, 2014 at 05:03:46PM +0100, Philipp Zabel wrote:
quoted
The PGC that is part of GPC controls isolation and power sequencing of the
power domains. The PU power domain will be handled by the generic pm domain
framework. It needs a phandle to the PU regulator to turn off power when
the domain is disabled and a list of clocks to be enabled during powerup
for reset propagation.
Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de>
---
Changes since v4:
- Use OF power domain bindings
- Added reset clocks
---
arch/arm/boot/dts/imx6sl.dtsi | 6 +++++-
1 file changed, 5 insertions(+), 1 deletion(-)
diff --git a/arch/arm/boot/dts/imx6sl.dtsi b/arch/arm/boot/dts/imx6sl.dtsi
index 28558f1..0e61262 100644
--- a/arch/arm/boot/dts/imx6sl.dtsi
+++ b/arch/arm/boot/dts/imx6sl.dtsi
@@ -529,9 +529,13 @@
};
gpc: gpc at 020dc000 {
- compatible = "fsl,imx6sl-gpc", "fsl,imx6q-gpc";
+ compatible = "fsl,imx6sl-gpc";
This change will break function imx_gpc_init(), which looks up
"fsl,imx6q-gpc" even on imx6sl.
Sorry, I'll drop this change.
regards
Philipp