Thread (19 messages) 19 messages, 7 authors, 2014-02-15

[PATCH 20/73] arm: use subsys_initcall in non-modular pl320 IPC code

flat view

From: arnd@arndb.de (Arnd Bergmann)
Date: 2014-01-21 21:44:57
Also in: linux-arch, lkml

On Tuesday 21 January 2014 16:22:23 Paul Gortmaker wrote:
Note that direct use of __initcall is discouraged, vs. one
of the priority categorized subgroups.  As __initcall gets
mapped onto device_initcall, our use of subsys_initcall (which
seems to make sense for netfilter code) will thus change this
registration from level 6-device to level 4-subsys (i.e. slightly
earlier).  However no impact of that small difference is expected.
This doesn't have anything to do with netfilter. The only user
of this driver at the moment is the highbank cpufreq driver, but
that could change.

	Arnd