Thread (16 messages) 16 messages, 4 authors, 2013-07-08
STALE4768d

[PATCH v3 4/6] ARM: dts: imx6q{dl}: fix the wrong RTS/CTS pad name

From: Lothar Waßmann <hidden>
Date: 2013-07-08 07:32:16
Also in: linux-serial

Hi,

Huang Shijie writes:
? 2013?07?07? 19:51, Lothar Wa?mann ??:
quoted
Hi,

Shawn Guo writes:
quoted
On Fri, Jul 05, 2013 at 02:12:30PM +0800, Huang Shijie wrote:
quoted
There is something wrong with the RTS/CTS pads:
   The RTS pad is assigned with the CTS's value;
   while the CTS pad is assigned with the RTS's value.
So basically, you are saying that select_input should be set up for CTS
rather than RTS.  It seems that the people who generated the macro got
the wrong input from developer.
programming 'select_input' only makes sense for inputs, not outputs.
Since CTS is an output signal, select_input only makes sense for the
RTS function of the pads.
Hi Lothar:

In our imx6 Soc, the CTS is used as a input signal, not as a output signal.

I checked two boards, one is imx6q ARM2 armidillo board, one is 
imx6-sabreauto board,
both the boards use the CTS as a input signal.
that's the problem with the DTE/DCE mode. Depending on the DCEDTE bit
in the UARTx_UFCR we would need different pad configurations for
RTS/CTS because in DCE mode CTS is an output and in DTE mode it's an
input.
Thus the correct pad config value would need the input_sel on the CTS
pad definition for DTE mode and on the RTS pad definition for DCE
mode. Maybe something like:
#define MX6Q_PAD_EIM_D19__UART1_DCE_CTS_B             0x09c 0x3b0 0x000 0x4 0x0
#define MX6Q_PAD_EIM_D19__UART1_DCE_RTS_B             0x09c 0x3b0 0x91c 0x4 0x0
#define MX6Q_PAD_EIM_D19__UART1_DTE_CTS_B             0x09c 0x3b0 0x91c 0x4 0x0
#define MX6Q_PAD_EIM_D19__UART1_DTE_RTS_B             0x09c 0x3b0 0x000 0x4 0x0


Lothar Wa?mann
-- 
___________________________________________________________

Ka-Ro electronics GmbH | Pascalstra?e 22 | D - 52076 Aachen
Phone: +49 2408 1402-0 | Fax: +49 2408 1402-10
Gesch?ftsf?hrer: Matthias Kaussen
Handelsregistereintrag: Amtsgericht Aachen, HRB 4996

www.karo-electronics.de | info at karo-electronics.de
___________________________________________________________