2009/9/2 Mark Brown [off-list ref]:
This looks basically good - my only concern is if the initialisation
data supplied for the regulators is just setting up the things that can
be set up via the API or if there's other stuff going on (this was my
reason for the question I asked the other day). ?If there's other stuff
being configured then I'm happy with the patch modulo the static thing.
OK so this array:
+ /* Set up regulators */
+ for (i = 0; i < ARRAY_SIZE(ab3100_reg_init_order); i++) {
+ err = ab3100_set_register_interruptible(ab3100,
+ ab3100_reg_init_order[i],
+ plfdata->reg_initvals[i]);
The initvals are one-byte registers for each regulator plus 2 bytes
of sleep settings for LDO E and BUCK respectively.
The sleep settings are driven by two HW lines, so a regulator
can react by suspending the regulator on line A or B disjunct
either (logical ||) or both (logical &&). (You don't alter that in
runtime so no API has been developed here.)
Apart from that it's just default-zero undefined bits and default
voltage and default on/off setting. It is mainly written here so
that we have a known state, eventhough the boot loader should
have set them up (thus boot_on for some of them). But I like
to be on the safe side. If you for example download the kernel
through something like JTAG you may not have executed the
boot loader, and the reset power-on defaults can be bad,
for example have regulators enabled that should not be.
Currently the framework will enable the .boot_on regulators
effectively setting this one bit right for all regulators.
For *some* of the boot_on regulators I could also use .apply_uV
to set the voltage bits of course, but only if min_uV
and max_uV is the same which is not the case for all
regulators that are default on here.
And I don't see any way for the core (set_machine_constraints)
to set regulators to *off* by default if they happen to be on at
boot.
So my conclusion is that the array of initial settings is really
needed to:
- Set sleep config bits (you don't want to alter this runtime BTW)
- Set some default voltage levels on variable regulators
- Set some regulators default off
- Thus establish a known initial state
OK?
Yours,
Linus Walleij