On Sat, Oct 17, 2026 at 10:06:08PM +0300, Jarkko Sakkinen wrote:
It has zero-copy data types for TPM2, it can interpret and present
both commands and response at the scale of the whole TCG spec, has
zero dependencies, does not allocate memory i.e. can point directly
into wire and is from the get go to be importable to an enclave
entry point, OS kernels and pre-boot firmware.
Enclave entry point would make sense if you wanted to do a vTPM.
I.e. it is also fully symmetric when it comes to the end point.