Re: RFC: Restricting userspace interfaces for CXL fabric management
From: Sreenivas Bagalkote <hidden>
Date: 2024-03-22 13:25:07
Also in:
linux-cxl, lkml
Jonathan,
What is the use case? My understanding so far is that clouds and similar sometimes use an in band path but it would be from a management only host, not a general purpose host running other software
The overwhelming majority of the PCIe switches get deployed in a single server. Typically four to eight switches are connected to two or more root complexes in one or two CPUs. The deployment scenario you have in mind - multiple physical hosts running general workloads and a management-only host - exists. But it is insignificant.
For telemetry(subject to any odd corners like commands that might lock the interface up for a long time, which we've seen with commands in the Spec!) I don't see any problem supporting those on all host software. They should be non destructive to other hosts etc.
Thank you. As you do this, please keep in mind that your concern about not affecting "other" hosts is theoretically valid but doesn't exist in the real world beyond science experiments. If there are real-world deployments, they are insignificant. I urge you all to make your stuff work with 99.99% of the deployments.
'Maybe' if you were to publish a specification for those particular vendor defined commands, it might be fine to add them to the allow list for the switch-cci.
Your proposal sounds reasonable. I will let you all experts figure out how to support the vendor-defined commands. CXL spec has them for a reason and they need to be supported. Sreeni On Fri, Mar 22, 2024 at 2:32 AM Jonathan Cameron < Jonathan.Cameron@huawei.com> wrote:
On Thu, 21 Mar 2024 14:41:00 -0700 Sreenivas Bagalkote [off-list ref] wrote:quoted
Thank you for kicking off this discussion, Jonathan.Hi Sreenivas,quoted
We need guidance from the community. 1. Datacenter customers must be able to manage PCIe switches in-band.What is the use case? My understanding so far is that clouds and similar sometimes use an in band path but it would be from a management only host, not a general purpose host running other software. Sure that control host just connects to a different upstream port so, from a switch point of view, it's the same as any other host. From a host software point of view it's not running general cloud workloads or (at least in most cases) a general purpose OS distribution. This is the key question behind this discussion.quoted
2. Management of switches includes getting health, performance, and error telemetry.For telemetry(subject to any odd corners like commands that might lock the interface up for a long time, which we've seen with commands in the Spec!) I don't see any problem supporting those on all host software. They should be non destructive to other hosts etc.quoted
3. These telemetry functions are not yet part of the CXL standardOk, so this we should try to pin down the boundaries around this. The thread linked below lays out the reasoning behind a general rule of not accepting vendor defined commands, but perhaps there are routes to answer some of those concerns. 'Maybe' if you were to publish a specification for those particular vendor defined commands, it might be fine to add them to the allow list for the switch-cci. Key here is that Broadcom would be committing to not using those particular opcodes from the vendor space for anything else in the future (so we could match on VID + opcode). This is similar to some DVSEC usage in PCIe (and why DVSEC is different from VSEC). Effectively you'd be publishing an additional specification building on CXL. Those are expected to surface anyway from various standards orgs - should we treat a company published one differently? I don't see why. Exactly how this would work might take some figuring out (in main code, separate driver module etc?) That specification would be expected to provide a similar level of detail to CXL spec defined commands (ideally the less vague ones, but meh, up to you as long as any side effects are clearly documented!) Speaking for myself, I'd consider this approach. Particularly true if I see clear effort in the standards org to push these into future specifications as that shows broadcom are trying to enhance the ecosystems.quoted
4. We built the CCI mailboxes into our PCIe switches per CXL spec and developed our management scheme around them. If the Linux community does not allow a CXL spec-compliant switch to be managed via the CXL spec-defined CCI mailbox, then please guide us on the right approach. Please tell us how you propose we manage our switches in-band.The Linux community is fine supporting this in the kernel (the BMC or Fabric Management only host case - option 2 below, so the code will be there) the question here is what advice we offer to the general purpose distributions and what protections we need to put in place to mitigate the 'blast radius' concerns. Jonathanquoted
Thank you Sreeni On Thu, Mar 21, 2024 at 10:44 AM Jonathan Cameron < Jonathan.Cameron@huawei.com> wrote:quoted
Hi All, This is has come up in a number of discussions both on list and inprivate,quoted
quoted
so I wanted to lay out a potential set of rules when deciding whetherorquoted
quoted
not to provide a user space interface for a particular feature of CXLFabricquoted
quoted
Management. The intent is to drive discussion, not to simply tellpeoplequoted
quoted
a set of rules. I've brought this to the public lists as it's a Linux kernel policy discussion, not a standards one. Whilst I'm writing the RFC this my attempt to summarize a possible position rather than necessarily being my personal view. It's a straw man - shoot at it! Not everyone in this discussion is familiar with relevant kernel or CXL concepts so I've provided more info than I normally would. First some background: ====================== CXL has two different types of Fabric. The comments here refer toboth, butquoted
quoted
for now the kernel stack is focused on the simpler VCS fabric, not themorequoted
quoted
recent Port Based Routing (PBR) Fabrics. A typical example for 2 hosts connected to a common switch looks something like: ________________ _______________ | | | | Hosts - each sees | HOST A | | HOST B | a PCIe style tree | | | | but from a fabric config | |Root Port| | | |Root Port| | point of view it'smorequoted
quoted
-------|-------- -------|------- complex. | | | | _______|______________________________|________ | USP (SW-CCI) USP | Switch can have lotsofquoted
quoted
| | | | Upstream Ports. Eachonequoted
quoted
| ____|________ _______|______ | has a virtualhierarchy.quoted
quoted
| | | | | | | vPPB vPPB vPPB vPPB| There are virtual | x | | | | "downstream ports."(vPPBs) | \ / / | That can be bound torealquoted
quoted
| \ / / | downstream ports. | \ / / | | \ / / | Multi LogicalDevices arequoted
quoted
| DSP0 DSP1 DSP 2 | support more than one vPPB ------------------------------------------------ bound to a single physical | | | DSP (transactions are tagged | | | with an LD-ID) SLD0 MLD0 SLD1 Some typical fabric management activities: 1) Bind/Unbind vPPB to physical DSP (Results in hotplug / unplugevents)quoted
quoted
2) Access config space or BAR space of End Points below the switch. 3) Tunneling messages through to devices downstream (e.g DynamicCapacityquoted
quoted
Forced Remove that will blow away some memory even if a host isusingquoted
quoted
it). 4) Non destructive stuff like status read back. Given the hosts may be using the Type 3 hosted memory (either Single Logical Device - SLD, or an LD on a Multi logical Device - MLD) as normalmemory,quoted
quoted
unbinding a device in use can result in the memory access from a different host being removed. The 'blast radius' is perhaps a rack of servers. This discussion applies equally to FM-API commands sent toMultiquoted
quoted
Head Devices (see CXL r3.1). The Fabric Management actions are done using the CXL spec definedFabricquoted
quoted
Management API, (FM-API) which is transported over various meansincludingquoted
quoted
OoB MCTP over your favourite transport (I2C, PCIe-VDM...) or via normal PCIe read/write to a Switch-CCI. A Switch-CCI is mailbox in PCI BAR space on a function found alongside one of the switch upstream ports; this mailbox is very similar to the MMPT definition found in PCIe r6.2. In many cases this switch CCI / MCTP connection is used by a BMC rather than a normal host, but there have been some questions raised aboutwhetherquoted
quoted
a general purpose server OS would have a valid reason to use thisinterfacequoted
quoted
(beyond debug and testing) to configure the switch or an MHD. If people have a use case for this, please reply to this thread to give more details. The most recently posted CXL Switch-CCI support only provided the RAWCXLquoted
quoted
command IOCTL interface that is already available for Type 3 memory devices. That allows for unfettered control of the switch but, because it is extremely easy to shoot yourself in the foot and cause unsolvable bug reports, it taints the kernel. There have been several requests to provide this interface without the taint for these switch configuration mailboxes. Last posted series:https://lore.kernel.org/all/20231016125323.18318-1-Jonathan.Cameron@huawei.com/ (local)quoted
quoted
Note there are unrelated reasons why that code hasn't been updatedsincequoted
quoted
v6.6 time, but I am planning to get back to it shortly. Similar issues will occur for other uses of PCIe MMPT (new mailbox inPCIquoted
quoted
that sometimes is used for similarly destructive activity such as PLDM based firmware update). On to the proposed rules: 1) Kernel space use of the various mailboxes, or filtered controls from user space.==================================================================================quoted
quoted
Absolutely fine - no one worries about this, but the mediated trafficwillquoted
quoted
be filtered for potentially destructive side effects. E.g. it willrejectquoted
quoted
attempts to change anything routing related if the kernel either knowsaquoted
quoted
host is using memory that will be blown away, or has no way to know (soaffectingquoted
quoted
routing to another host). This includes blocking 'all' vendor defined messages as we have no idea what the do. Note this means the kernelhasquoted
quoted
an allow list and new commands are not initially allowed. This isn't currently enabled for Switch CCIs because they are onlyreallyquoted
quoted
interesting if the potentially destructive stuff is available (anearlierquoted
quoted
version did enable query commands, but it wasn't particularly useful to know what your switch could do but not be allowed to do any of it). If you take a MMPT usecase of PLDM firmware update, the filtering would check that the device was in a state where a firmware update won't rip memory out from under a host, which would be messy if that host is doing the update. 2) Unfiltered userspace use of mailbox for Fabric Management - BMCkernelsquoted
quoted
==========================================================================quoted
quoted
(This would just be a kernel option that we'd advise normal server distributions not to turn on. Would be enabled by openBMC etc) This is fine - there is some work to do, but the switch-cci PCI driver will hopefully be ready for upstream merge soon. There is no filteringofquoted
quoted
accesses. Think of this as similar to all the damage you can do via MCTP from a BMC. Similarly it is likely that much of the complexity of the actual commands will be left to user space tooling: https://gitlab.com/jic23/cxl-fmapi-tests has some test examples. Whether Kconfig help text is strong enough to ensure this only gets enabled for BMC targeted distros is an open question we can address alongside an updated patch set. (On to the one that the "debate" is about) 3) Unfiltered user space use of mailbox for Fabric Management - Distro kernels=============================================================================quoted
quoted
(General purpose Linux Server Distro (Redhat, Suse etc)) This is equivalent of RAW command support on CXL Type 3 memory devices. You can enable those in a distro kernel build despite the scary config help text, but if you use it the kernel is tainted. The result of the taint is to add a flag to bug reports and print a big messageto sayquoted
quoted
that you've used a feature that might result in you shooting yourself in the foot. The taint is there because software is not at first written to dealwithquoted
quoted
everything that can happen smoothly (e.g. surprise removal) It's hard to survive some of these events, so is never on the initial featurelistquoted
quoted
for any bus, so this flag is just to indicate we have entered a world where almost all bets are off wrt to stability. We might not know what a command does so we can't assess the impact (and no one trusts vendor commands to report affects right in the Command Effects Log - which in theory tells you if a command can result problems). A concern was raised about GAE/FAST/LDST tables for CXL Fabrics (a r3.1 feature) but, as I understand it, these are intended for a host to configure and should not have side effects on other hosts? My working assumption is that the kernel driver stack will handle these (once we catch up with the current feature backlog!) Currently we have no visibility of what the OS driver stack for a fabrics will actually look like - the spec is just the starting point for that. (patches welcome ;) The various CXL upstream developers and maintainers may have differing views of course, but my current understanding is we want to support 1 and 2, but are very resistant to 3! General Notes ============= One side aspect of why we really don't like unfiltered userspaceaccess toquoted
quoted
any of these devices is that people start building non standard hacks inand wequoted
quoted
lose the ecosystem advantages. Forcing a considered discussion +patchesquoted
quoted
to let a particular command be supported, drives standardization.https://lore.kernel.org/linux-cxl/CAPcyv4gDShAYih5iWabKg_eTHhuHm54vEAei8ZkcmHnPp3B0cw@mail.gmail.com/ (local)quoted
quoted
provides some history on vendor specific extensions and why in generalwequoted
quoted
won't support them upstream. To address another question raised in an earlier discussion: Putting these Fabric Management interfaces behind guard rails of sometypequoted
quoted
(e.g. CONFIG_IM_A_BMC_AND_CAN_MAKE_A_MESS) does not encourage the risk of non standard interfaces, because we will be even less likely toacceptquoted
quoted
those upstream! If anyone needs more details on any aspect of this please ask. There are a lot of things involved and I've only tried to give a fairly minimal illustration to drive the discussion. I may well have missed something crucial. Jonathan
-- This electronic communication and the information and any files transmitted with it, or attached to it, are confidential and are intended solely for the use of the individual or entity to whom it is addressed and may contain information that is confidential, legally privileged, protected by privacy laws, or otherwise restricted from disclosure to anyone else. If you are not the intended recipient or the person responsible for delivering the e-mail to the intended recipient, you are hereby notified that any use, copying, distributing, dissemination, forwarding, printing, or copying of this e-mail is strictly prohibited. If you received this e-mail in error, please return the e-mail to the sender, delete it from your computer, and destroy any printed copy of it.