Nicolas Dichtel [off-list ref] writes:
Le 30/10/2014 19:41, Eric W. Biederman a écrit :
quoted
Nicolas Dichtel [off-list ref] writes:
quoted
The goal of this serie is to be able to multicast netlink messages with an
attribute that identify a peer netns.
This is needed by the userland to interpret some informations contained in
netlink messages (like IFLA_LINK value, but also some other attributes in case
of x-netns netdevice (see also
http://thread.gmane.org/gmane.linux.network/315933/focus=316064 and
http://thread.gmane.org/gmane.linux.kernel.containers/28301/focus=4239)).
Ids of peer netns are set by userland via a new genl messages. These ids are
stored per netns and are local (ie only valid in the netns where they are set).
To avoid allocating an int for each peer netns, I use idr_for_each() to retrieve
the id of a peer netns. Note that it will be possible to add a table (struct net
-> id) later to optimize this lookup if needed.
Patch 1/4 introduces the netlink API mechanism to set and get these ids.
Patch 2/4 and 3/4 implements an example of how to use these ids in rtnetlink
messages. And patch 4/4 shows that the netlink messages can be symetric between
a GET and a SET.
iproute2 patches are available, I can send them on demand.
A quick reply. I think this patchset is in the right general direction.
There are some oddball details that seem odd/awkward to me such as using
genetlink instead of rtnetlink to get and set the ids, and not having
ids if they are not set (that feels like a maintenance/usability challenge).
No problem to use rtnetlink, in fact, I hesitated.
For the second point, I'm not sure to follow you: how to have an id, which will
not break migration, without asking the user to set it?
We have that situtation with ifindex already. Basically the thought is
to allow an id to be set, but also allow an id to be auto-generated if
we use an namespace without an id being set.
My gut says if we can figure that out we will have an interface with
much more utility.
Note that if the user does not provide an id, you still have a magic value to
say "it's a peer netns but we don't know which one".
That is certainly an improvement in clarity over where we are today.
quoted
I would like to give your patches a deep review, but I won't be able to
do that for a couple of weeks. I am deep in the process of moving,
and will be mostly offline until about the Nov 11th.
No problem, I will wait.
I would be great to get a final version for the 3.19 ;-)
Eric
_______________________________________________
Containers mailing list
Containers@lists.linux-foundation.org
https://lists.linuxfoundation.org/mailman/listinfo/containers