Thread (24 messages) 24 messages, 5 authors, 2017-03-27

Re: [PATCH 4/8] net/i40e: set TC strict priority mode

From: Wu, Jingjing <hidden>
Date: 2017-03-24 05:20:08

quoted hunk ↗ jump to hunk
-----Original Message-----
From: dev [mailto:dev-bounces@dpdk.org] On Behalf Of Wenzhuo Lu
Sent: Friday, February 24, 2017 11:25 AM
To: dev@dpdk.org
Cc: Lu, Wenzhuo <redacted>
Subject: [dpdk-dev] [PATCH 4/8] net/i40e: set TC strict priority mode

Set some TCs to strict priority mode.
It's a global setting on a physical port.

Signed-off-by: Wenzhuo Lu <redacted>
---
 doc/guides/nics/i40e.rst                  |  10 +++
 doc/guides/rel_notes/release_17_05.rst    |   7 ++
 drivers/net/i40e/i40e_ethdev.c            | 119
++++++++++++++++++++++++++++++
 drivers/net/i40e/i40e_ethdev.h            |   1 +
 drivers/net/i40e/rte_pmd_i40e.h           |  15 ++++
 drivers/net/i40e/rte_pmd_i40e_version.map |   1 +
 6 files changed, 153 insertions(+)
diff --git a/doc/guides/nics/i40e.rst b/doc/guides/nics/i40e.rst index
260287e..361d9d9 100644
--- a/doc/guides/nics/i40e.rst
+++ b/doc/guides/nics/i40e.rst
@@ -478,3 +478,13 @@ enabled. If so, return failure.
 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
is enabled. If so, disable per VF max bandwidth and continue with per TC max
bandwidth setting.
+
+TC TX scheduling mode setting
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+There're 2 TX scheduling modes for TCs, round robin and strict priority mode.
+If a TC is set to strict priority mode, it can consume unlimited bandwidth.
+It means if APP has set the max bandwidth for that TC, it comes to no
+effect.
+It's suggested to set the strict priority mode for a TC that is latency
+sensitive but no consuming much bandwidth.
diff --git a/doc/guides/rel_notes/release_17_05.rst
b/doc/guides/rel_notes/release_17_05.rst
index d31435c..99811a2 100644
--- a/doc/guides/rel_notes/release_17_05.rst
+++ b/doc/guides/rel_notes/release_17_05.rst
@@ -55,6 +55,13 @@ New Features
   i40e HW supports to set the max bandwidth for a TC on a VF. Enable this
   capability.

+* **Added TC strict priority mode setting on i40e.**
+
+  There're 2 TX scheduling modes supported for TCs by i40e HW, round
+ ribon mode  and strict priority mode. By default it's round robin
+ mode. Enable the  capability to change the TX scheduling mode for a
+ TC. It's a global setting  on a physical port.
+
 Resolved Issues
quoted hunk ↗ jump to hunk
+	if (!veb->strict_prio_tc)
+		ret = i40e_aq_config_switch_comp_ets(
+			hw, veb->uplink_seid,
+			&ets_data, i40e_aqc_opc_enable_switching_comp_ets,
+			NULL);
How about to check the tc_map when the first time to set strict_prio_tc?