Thread (12 messages) 12 messages, 5 authors, 2016-08-26

Re: vhost [query] : support for multiple ports and non VMDQ devices in vhost switch

From: Yuanhan Liu <hidden>
Date: 2016-08-16 02:47:46

On Tue, Aug 09, 2016 at 04:42:33PM +0530, Pankaj Chauhan wrote:
Hi,

I am working on an NXP platform where we intend to use user space vhost
switch (examples/vhost) as backend for VIRTIO devices. But there are two
limitations in current vhost-switch (examples/vhost)that are restricting my
use case:

1. The vhost-switch application is tightly integrated with Intel VMDQ. Since
my device doesn't have VMDQ i can not use this application directly.
Sorry being late (I was on biz trip last week).

Yes, a vhost example should not do that. We have an internal TODO to
remove it. Actually, to make it optional, and Jianfeng was working on
that. Well, seems that you two have already had some discussions.
2. The vhost-switch application supports only one external or physical port
(non virtio devices), but my requirement is to have multiple physical ports
and multiple virtio devices.
What are you going to achieve? BTW, have you tried testpmd (with vhost-pmd)?
I'm with impression that it might be a better option to you.

	--yliu
In summary my requirement is to do whatever vhost-switch is doing, in
addition to that add support for following:

1. support devices that don't have VMDQ.
2. Support multiple physical ports.

I need suggestions on the approach i should take: whether to add support of
above mentioned in existing vhost-switch (examples/vhost) or write another
application (based on librte_vhost only) to support my requirements.

I'll work on it after the suggestion i get from the list, and send the RFC
patch.

Thanks,
Pankaj