# Re: \[RFC PATCH net-next 0/7\] net: phy: introduce phy numbering

- From: Andrew Lunn \<andrew@lunn.ch\>
- Date: 2023-09-14 12:47:55 
- List: netdev
- Page: https://ratatoskr.run/netdev/2023/09/2334579
- Thread: https://ratatoskr.run/netdev/2023/09/2326448/t.md

```text
> FWIW when thinking about multiple PHY to a single MAC, what comes to my 
> mind is the SIS 900 board, and its driver net/ethernet/sis/sis900.c
> 
> It has a function sis900_default_phy() that loops over all phys to find 
> one with up-link then to put all but that one in ISOLATE mode. Then when 
> the link goes down it loops again to find another up-link.
> 
> I guess your series would also help in that case, wouldn't it ?

Yes, it would. However, that driver would need its PHY handling
re-written because it is using the old MII code, not phylib.

	Andrew
```