# Re: \[PATCH\] net: phy: at803x: Improve hibernation support on start up

- From: Oleksij Rempel \<o.rempel@pengutronix.de\>
- Date: 2023-08-10 04:32:59 
- List: netdev
- Page: https://ratatoskr.run/netdev/2023/08/11268900
- Thread: https://ratatoskr.run/netdev/2023/08/11268287/t.md

```text
On Thu, Aug 10, 2023 at 02:49:55AM +0200, Marek Vasut wrote:
> On 8/10/23 00:06, Andrew Lunn wrote:
> > On Wed, Aug 09, 2023 at 11:34:19PM +0200, Marek Vasut wrote:
> > > On 8/9/23 15:40, Andrew Lunn wrote:
> > > > > > Hm.. how about officially defining this PHY as the clock provider and disable
> > > > > > PHY automatic hibernation as long as clock is acquired?
> > > > > > 
> > > > > Sorry, I don't know much about the clock provider/consumer, but I think there
> > > > > will be more changes if we use clock provider/consume mechanism.
> > > > 
> > > > Less changes is not always best. What happens when a different PHY is
> > > > used?
> > > 
> > > Then the system wouldn't be affected by this AR803x specific behavior.
> > 
> > Do you know it really is specific to the AR803x? Turning the clock off
> > seams a reasonable thing to do when saving power, or when there is no
> > link partner.
> 
> This hibernation behavior seem specific to this PHY, I haven't seen it on
> another PHY connected to the EQoS so far.

Hm.. if I see it correctly I have right now kind of similar issues with
Microchip KSZ9893 switch attached to EQoS. The switch is clock
provider and I need to make sure that switch has CPU port enabled before
probing the ethernet controller.

-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |
```