[PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

Subsystems: can network layer, can-j1939 network layer, the rest

STALE1752d LANDED

Landed in mainline as 379743985ab6 on 2021-10-17.

14 messages, 4 authors, 2021-10-17 · open the first message on its own page

[PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Zhang Changzhong <hidden>
Date: 2021-09-30 03:29:49

According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.

Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
---
 net/can/j1939/transport.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index bb5c4b8..eedaeaf 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
 static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 				 struct sk_buff *skb)
 {
+	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
 	struct j1939_priv *priv = session->priv;
 	struct j1939_sk_buff_cb *skcb, *se_skcb;
 	struct sk_buff *se_skb = NULL;
@@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 
 	skcb = j1939_skb_to_cb(skb);
 	dat = skb->data;
-	if (skb->len <= 1)
+	if (skb->len != 8) {
 		/* makes no sense */
+		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
 		goto out_session_cancel;
+	}
 
 	switch (session->last_cmd) {
 	case 0xff:
@@ -1904,7 +1907,7 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
  out_session_cancel:
 	kfree_skb(se_skb);
 	j1939_session_timers_cancel(session);
-	j1939_session_cancel(session, J1939_XTP_ABORT_FAULT);
+	j1939_session_cancel(session, abort);
 	j1939_session_put(session);
 }
 
-- 
2.9.5

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Kurt Van Dijck <hidden>
Date: 2021-09-30 07:56:12

On Thu, 30 Sep 2021 11:33:20 +0800, Zhang Changzhong wrote:
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.
SAE-j1939-21 indeed says that all TP.DT must be 8 bytes.
However, the last TP.DT may contain up to 6 stuff bytes, which have no meaning.
If I remember well, they are even not 'reserved'.
quoted hunk
Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
---
 net/can/j1939/transport.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index bb5c4b8..eedaeaf 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
 static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 				 struct sk_buff *skb)
 {
+	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
 	struct j1939_priv *priv = session->priv;
 	struct j1939_sk_buff_cb *skcb, *se_skcb;
 	struct sk_buff *se_skb = NULL;
@@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 
 	skcb = j1939_skb_to_cb(skb);
 	dat = skb->data;
-	if (skb->len <= 1)
+	if (skb->len != 8) {
 		/* makes no sense */
+		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
 		goto out_session_cancel;
I think this is a situation of
"be strict on what you send, be tolerant on what you receive".

Did you find a technical reason to abort a session because the last frame didn't
bring overhead that you don't use?

Kind regards,
Kurt
quoted hunk
+	}
 
 	switch (session->last_cmd) {
 	case 0xff:
@@ -1904,7 +1907,7 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
  out_session_cancel:
 	kfree_skb(se_skb);
 	j1939_session_timers_cancel(session);
-	j1939_session_cancel(session, J1939_XTP_ABORT_FAULT);
+	j1939_session_cancel(session, abort);
 	j1939_session_put(session);
 }
 
-- 
2.9.5

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Zhang Changzhong <hidden>
Date: 2021-10-08 09:22:19

Hi Kurt,
Sorry for the late reply.

On 2021/9/30 15:42, Kurt Van Dijck wrote:
On Thu, 30 Sep 2021 11:33:20 +0800, Zhang Changzhong wrote:
quoted
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.
SAE-j1939-21 indeed says that all TP.DT must be 8 bytes.
However, the last TP.DT may contain up to 6 stuff bytes, which have no meaning.
If I remember well, they are even not 'reserved'.
Agree, these bytes are meaningless for last TP.DT.
quoted
Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
---
 net/can/j1939/transport.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index bb5c4b8..eedaeaf 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
 static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 				 struct sk_buff *skb)
 {
+	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
 	struct j1939_priv *priv = session->priv;
 	struct j1939_sk_buff_cb *skcb, *se_skcb;
 	struct sk_buff *se_skb = NULL;
@@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 
 	skcb = j1939_skb_to_cb(skb);
 	dat = skb->data;
-	if (skb->len <= 1)
+	if (skb->len != 8) {
 		/* makes no sense */
+		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
 		goto out_session_cancel;
I think this is a situation of
"be strict on what you send, be tolerant on what you receive".

Did you find a technical reason to abort a session because the last frame didn't
bring overhead that you don't use?
No technical reason. The only reason is that SAE-J1939-82 requires responder
to abort session if any TP.DT less than 8 bytes (section A.3.4, Row 7).

Best regards,
Changzhong
Kind regards,
Kurt
quoted
+	}
 
 	switch (session->last_cmd) {
 	case 0xff:
@@ -1904,7 +1907,7 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
  out_session_cancel:
 	kfree_skb(se_skb);
 	j1939_session_timers_cancel(session);
-	j1939_session_cancel(session, J1939_XTP_ABORT_FAULT);
+	j1939_session_cancel(session, abort);
 	j1939_session_put(session);
 }
 
-- 
2.9.5
.

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Oleksij Rempel <o.rempel@pengutronix.de>
Date: 2021-10-08 11:00:34

On Fri, Oct 08, 2021 at 05:22:12PM +0800, Zhang Changzhong wrote:
Hi Kurt,
Sorry for the late reply.

On 2021/9/30 15:42, Kurt Van Dijck wrote:
quoted
On Thu, 30 Sep 2021 11:33:20 +0800, Zhang Changzhong wrote:
quoted
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.
SAE-j1939-21 indeed says that all TP.DT must be 8 bytes.
However, the last TP.DT may contain up to 6 stuff bytes, which have no meaning.
If I remember well, they are even not 'reserved'.
Agree, these bytes are meaningless for last TP.DT.
quoted
quoted
Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
---
 net/can/j1939/transport.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index bb5c4b8..eedaeaf 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
 static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 				 struct sk_buff *skb)
 {
+	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
 	struct j1939_priv *priv = session->priv;
 	struct j1939_sk_buff_cb *skcb, *se_skcb;
 	struct sk_buff *se_skb = NULL;
@@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 
 	skcb = j1939_skb_to_cb(skb);
 	dat = skb->data;
-	if (skb->len <= 1)
+	if (skb->len != 8) {
 		/* makes no sense */
+		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
 		goto out_session_cancel;
I think this is a situation of
"be strict on what you send, be tolerant on what you receive".

Did you find a technical reason to abort a session because the last frame didn't
bring overhead that you don't use?
No technical reason. The only reason is that SAE-J1939-82 requires responder
to abort session if any TP.DT less than 8 bytes (section A.3.4, Row 7).
Do you mean: "BAM Transport: Ensure DUT discards BAM transport when
TP.DT data packets are not correct size" ... "Verify DUT discards the
BAM transport if any TP.DT data packet has less than 8 bytes"?

Regards,
Oleksij
-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Kurt Van Dijck <hidden>
Date: 2021-10-08 17:09:46

On Fri, 08 Oct 2021 13:00:07 +0200, Oleksij Rempel wrote:
On Fri, Oct 08, 2021 at 05:22:12PM +0800, Zhang Changzhong wrote:
quoted
Hi Kurt,
Sorry for the late reply.

On 2021/9/30 15:42, Kurt Van Dijck wrote:
quoted
On Thu, 30 Sep 2021 11:33:20 +0800, Zhang Changzhong wrote:
quoted
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.
SAE-j1939-21 indeed says that all TP.DT must be 8 bytes.
However, the last TP.DT may contain up to 6 stuff bytes, which have no meaning.
If I remember well, they are even not 'reserved'.
Agree, these bytes are meaningless for last TP.DT.
quoted
quoted
Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
---
 net/can/j1939/transport.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index bb5c4b8..eedaeaf 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
 static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 				 struct sk_buff *skb)
 {
+	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
 	struct j1939_priv *priv = session->priv;
 	struct j1939_sk_buff_cb *skcb, *se_skcb;
 	struct sk_buff *se_skb = NULL;
@@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 
 	skcb = j1939_skb_to_cb(skb);
 	dat = skb->data;
-	if (skb->len <= 1)
+	if (skb->len != 8) {
 		/* makes no sense */
+		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
 		goto out_session_cancel;
I think this is a situation of
"be strict on what you send, be tolerant on what you receive".

Did you find a technical reason to abort a session because the last frame didn't
bring overhead that you don't use?
No technical reason. The only reason is that SAE-J1939-82 requires responder
to abort session if any TP.DT less than 8 bytes (section A.3.4, Row 7).
IMHO, this is some kind of laziness to make the exception for the last TP.DT.

I attended an ISOBUS certification (back in 2013) where the transmitting
node effectively stripped the trailing bytes, and this 'deviation' was
not even noticed.

This change applies to the receiving side. Would a sender that
leaves the trailing bytes want you to discard the session bacause of this?
So the spirit of the SAE-J1939-82 is, in this case, different from
the strict literal interpretation.
Do you mean: "BAM Transport: Ensure DUT discards BAM transport when
TP.DT data packets are not correct size" ... "Verify DUT discards the
BAM transport if any TP.DT data packet has less than 8 bytes"?
Kind regards,
Kurt

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Zhang Changzhong <hidden>
Date: 2021-10-09 08:44:04

On 2021/10/8 19:00, Oleksij Rempel wrote:
On Fri, Oct 08, 2021 at 05:22:12PM +0800, Zhang Changzhong wrote:
quoted
Hi Kurt,
Sorry for the late reply.

On 2021/9/30 15:42, Kurt Van Dijck wrote:
quoted
On Thu, 30 Sep 2021 11:33:20 +0800, Zhang Changzhong wrote:
quoted
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.
SAE-j1939-21 indeed says that all TP.DT must be 8 bytes.
However, the last TP.DT may contain up to 6 stuff bytes, which have no meaning.
If I remember well, they are even not 'reserved'.
Agree, these bytes are meaningless for last TP.DT.
quoted
quoted
Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
---
 net/can/j1939/transport.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index bb5c4b8..eedaeaf 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
 static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 				 struct sk_buff *skb)
 {
+	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
 	struct j1939_priv *priv = session->priv;
 	struct j1939_sk_buff_cb *skcb, *se_skcb;
 	struct sk_buff *se_skb = NULL;
@@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 
 	skcb = j1939_skb_to_cb(skb);
 	dat = skb->data;
-	if (skb->len <= 1)
+	if (skb->len != 8) {
 		/* makes no sense */
+		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
 		goto out_session_cancel;
I think this is a situation of
"be strict on what you send, be tolerant on what you receive".

Did you find a technical reason to abort a session because the last frame didn't
bring overhead that you don't use?
No technical reason. The only reason is that SAE-J1939-82 requires responder
to abort session if any TP.DT less than 8 bytes (section A.3.4, Row 7).
Do you mean: "BAM Transport: Ensure DUT discards BAM transport when
TP.DT data packets are not correct size" ... "Verify DUT discards the
BAM transport if any TP.DT data packet has less than 8 bytes"?
Yes.

Regards,
Changzhong
Regards,
Oleksij

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Zhang Changzhong <hidden>
Date: 2021-10-09 09:13:01

On 2021/10/9 1:09, Kurt Van Dijck wrote:
On Fri, 08 Oct 2021 13:00:07 +0200, Oleksij Rempel wrote:
quoted
On Fri, Oct 08, 2021 at 05:22:12PM +0800, Zhang Changzhong wrote:
quoted
Hi Kurt,
Sorry for the late reply.

On 2021/9/30 15:42, Kurt Van Dijck wrote:
quoted
On Thu, 30 Sep 2021 11:33:20 +0800, Zhang Changzhong wrote:
quoted
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.
SAE-j1939-21 indeed says that all TP.DT must be 8 bytes.
However, the last TP.DT may contain up to 6 stuff bytes, which have no meaning.
If I remember well, they are even not 'reserved'.
Agree, these bytes are meaningless for last TP.DT.
quoted
quoted
Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
---
 net/can/j1939/transport.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index bb5c4b8..eedaeaf 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
 static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 				 struct sk_buff *skb)
 {
+	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
 	struct j1939_priv *priv = session->priv;
 	struct j1939_sk_buff_cb *skcb, *se_skcb;
 	struct sk_buff *se_skb = NULL;
@@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 
 	skcb = j1939_skb_to_cb(skb);
 	dat = skb->data;
-	if (skb->len <= 1)
+	if (skb->len != 8) {
 		/* makes no sense */
+		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
 		goto out_session_cancel;
I think this is a situation of
"be strict on what you send, be tolerant on what you receive".

Did you find a technical reason to abort a session because the last frame didn't
bring overhead that you don't use?
No technical reason. The only reason is that SAE-J1939-82 requires responder
to abort session if any TP.DT less than 8 bytes (section A.3.4, Row 7).
IMHO, this is some kind of laziness to make the exception for the last TP.DT.

I attended an ISOBUS certification (back in 2013) where the transmitting
node effectively stripped the trailing bytes, and this 'deviation' was
not even noticed.
I found that SAE-J1939-82 contains the following test:
"BAM Transport: Ensure extra (unused) bytes of last Data Transfer data packet
is/are filled-in correctly. (DUT as Originator)" ... "Verify last TP.DT data
packet for a BAM transport is sent with an 8 byte data field and the unused
bytes of this packet are filled with FF" (section A.3.3, Row 8).

So the J1939 compliance test can detect this kind of 'deviation', perhaps
ISOBUS certification does not do this check?
This change applies to the receiving side. Would a sender that
leaves the trailing bytes want you to discard the session bacause of this?
So the spirit of the SAE-J1939-82 is, in this case, different from
the strict literal interpretation.
Such packets should not be sent if the sender complies with SAE-J1939-82, but
if the transmitting node you mentioned above exist on the network, this patch
will casue their sessions to be aborted. From this point of view, I think it is
reasonable to drop this patch.

Regards,
Changzhong
quoted
Do you mean: "BAM Transport: Ensure DUT discards BAM transport when
TP.DT data packets are not correct size" ... "Verify DUT discards the
BAM transport if any TP.DT data packet has less than 8 bytes"?
Kind regards,
Kurt
.

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Oleksij Rempel <o.rempel@pengutronix.de>
Date: 2021-10-11 06:35:26

On Sat, Oct 09, 2021 at 04:43:56PM +0800, Zhang Changzhong wrote:
On 2021/10/8 19:00, Oleksij Rempel wrote:
quoted
On Fri, Oct 08, 2021 at 05:22:12PM +0800, Zhang Changzhong wrote:
quoted
Hi Kurt,
Sorry for the late reply.

On 2021/9/30 15:42, Kurt Van Dijck wrote:
quoted
On Thu, 30 Sep 2021 11:33:20 +0800, Zhang Changzhong wrote:
quoted
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.
SAE-j1939-21 indeed says that all TP.DT must be 8 bytes.
However, the last TP.DT may contain up to 6 stuff bytes, which have no meaning.
If I remember well, they are even not 'reserved'.
Agree, these bytes are meaningless for last TP.DT.
quoted
quoted
Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
---
 net/can/j1939/transport.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index bb5c4b8..eedaeaf 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
 static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 				 struct sk_buff *skb)
 {
+	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
 	struct j1939_priv *priv = session->priv;
 	struct j1939_sk_buff_cb *skcb, *se_skcb;
 	struct sk_buff *se_skb = NULL;
@@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 
 	skcb = j1939_skb_to_cb(skb);
 	dat = skb->data;
-	if (skb->len <= 1)
+	if (skb->len != 8) {
 		/* makes no sense */
+		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
 		goto out_session_cancel;
I think this is a situation of
"be strict on what you send, be tolerant on what you receive".

Did you find a technical reason to abort a session because the last frame didn't
bring overhead that you don't use?
No technical reason. The only reason is that SAE-J1939-82 requires responder
to abort session if any TP.DT less than 8 bytes (section A.3.4, Row 7).
Do you mean: "BAM Transport: Ensure DUT discards BAM transport when
TP.DT data packets are not correct size" ... "Verify DUT discards the
BAM transport if any TP.DT data packet has less than 8 bytes"?
Yes.
OK, then I have some problems to understand this part:
- 5.10.2.4 Connection Closure
  The “connection abort” message is not allowed to be used by responders in the
  case of a global destination (i.e. BAM).

My assumption would be: In case of broadcast transfer, multiple MCU are
receivers. If one of MCU was not able to get complete TP.DT, it should
not abort BAM for all.

So, "DUT discards the BAM transport" sounds for me as local action.
Complete TP would be dropped locally.

Regards
Oleksij
-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Kurt Van Dijck <hidden>
Date: 2021-10-11 07:18:49

On Mon, 11 Oct 2021 08:35:07 +0200, Oleksij Rempel wrote:
On Sat, Oct 09, 2021 at 04:43:56PM +0800, Zhang Changzhong wrote:
quoted
On 2021/10/8 19:00, Oleksij Rempel wrote:
quoted
On Fri, Oct 08, 2021 at 05:22:12PM +0800, Zhang Changzhong wrote:
quoted
Hi Kurt,
Sorry for the late reply.

On 2021/9/30 15:42, Kurt Van Dijck wrote:
quoted
On Thu, 30 Sep 2021 11:33:20 +0800, Zhang Changzhong wrote:
quoted
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.
SAE-j1939-21 indeed says that all TP.DT must be 8 bytes.
However, the last TP.DT may contain up to 6 stuff bytes, which have no meaning.
If I remember well, they are even not 'reserved'.
Agree, these bytes are meaningless for last TP.DT.
quoted
quoted
[...]
quoted
quoted
quoted
quoted
I think this is a situation of
"be strict on what you send, be tolerant on what you receive".

Did you find a technical reason to abort a session because the last frame didn't
bring overhead that you don't use?
No technical reason. The only reason is that SAE-J1939-82 requires responder
to abort session if any TP.DT less than 8 bytes (section A.3.4, Row 7).
Do you mean: "BAM Transport: Ensure DUT discards BAM transport when
TP.DT data packets are not correct size" ... "Verify DUT discards the
BAM transport if any TP.DT data packet has less than 8 bytes"?
Yes.
OK, then I have some problems to understand this part:
- 5.10.2.4 Connection Closure
  The “connection abort” message is not allowed to be used by responders in the
  case of a global destination (i.e. BAM).

My assumption would be: In case of broadcast transfer, multiple MCU are
receivers. If one of MCU was not able to get complete TP.DT, it should
not abort BAM for all.
There is indeed no action defined to abort at BAM.
So, "DUT discards the BAM transport" sounds for me as local action.
Complete TP would be dropped locally.
exact.

Kurt

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Zhang Changzhong <hidden>
Date: 2021-10-11 10:40:23

On 2021/10/11 14:35, Oleksij Rempel wrote:
On Sat, Oct 09, 2021 at 04:43:56PM +0800, Zhang Changzhong wrote:
quoted
On 2021/10/8 19:00, Oleksij Rempel wrote:
quoted
On Fri, Oct 08, 2021 at 05:22:12PM +0800, Zhang Changzhong wrote:
quoted
Hi Kurt,
Sorry for the late reply.

On 2021/9/30 15:42, Kurt Van Dijck wrote:
quoted
On Thu, 30 Sep 2021 11:33:20 +0800, Zhang Changzhong wrote:
quoted
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.
SAE-j1939-21 indeed says that all TP.DT must be 8 bytes.
However, the last TP.DT may contain up to 6 stuff bytes, which have no meaning.
If I remember well, they are even not 'reserved'.
Agree, these bytes are meaningless for last TP.DT.
quoted
quoted
Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
---
 net/can/j1939/transport.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index bb5c4b8..eedaeaf 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
 static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 				 struct sk_buff *skb)
 {
+	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
 	struct j1939_priv *priv = session->priv;
 	struct j1939_sk_buff_cb *skcb, *se_skcb;
 	struct sk_buff *se_skb = NULL;
@@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 
 	skcb = j1939_skb_to_cb(skb);
 	dat = skb->data;
-	if (skb->len <= 1)
+	if (skb->len != 8) {
 		/* makes no sense */
+		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
 		goto out_session_cancel;
I think this is a situation of
"be strict on what you send, be tolerant on what you receive".

Did you find a technical reason to abort a session because the last frame didn't
bring overhead that you don't use?
No technical reason. The only reason is that SAE-J1939-82 requires responder
to abort session if any TP.DT less than 8 bytes (section A.3.4, Row 7).
Do you mean: "BAM Transport: Ensure DUT discards BAM transport when
TP.DT data packets are not correct size" ... "Verify DUT discards the
BAM transport if any TP.DT data packet has less than 8 bytes"?
Yes.
OK, then I have some problems to understand this part:
- 5.10.2.4 Connection Closure
  The “connection abort” message is not allowed to be used by responders in the
  case of a global destination (i.e. BAM).

My assumption would be: In case of broadcast transfer, multiple MCU are
receivers. If one of MCU was not able to get complete TP.DT, it should
not abort BAM for all.

So, "DUT discards the BAM transport" sounds for me as local action.
Complete TP would be dropped locally.
Yeah, you are right. With this patch receivers drop BAM transport locally
because j1939_session_cancel() only send abort message in RTS/CTS transport.

For RTS/CTS transport, SAE-J1939-82 also has similar requirements:
"RTS/CTS Transport: Data field size of Transport Data packets for RTS/CTS
(DUT as Responder)"..."Verify DUT behavior, e.g., sends a TP.CM_CTS to have
packets resent or sends a TP.Conn_Abort, when it receives TP.DT data packets
with less than 8 bytes" (section A.3.6, Row 18)

Regards,
Changzhong
.

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Oleksij Rempel <o.rempel@pengutronix.de>
Date: 2021-10-12 10:21:46

On Mon, Oct 11, 2021 at 06:40:15PM +0800, Zhang Changzhong wrote:
On 2021/10/11 14:35, Oleksij Rempel wrote:
quoted
On Sat, Oct 09, 2021 at 04:43:56PM +0800, Zhang Changzhong wrote:
quoted
On 2021/10/8 19:00, Oleksij Rempel wrote:
quoted
On Fri, Oct 08, 2021 at 05:22:12PM +0800, Zhang Changzhong wrote:
quoted
Hi Kurt,
Sorry for the late reply.

On 2021/9/30 15:42, Kurt Van Dijck wrote:
quoted
On Thu, 30 Sep 2021 11:33:20 +0800, Zhang Changzhong wrote:
quoted
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.
SAE-j1939-21 indeed says that all TP.DT must be 8 bytes.
However, the last TP.DT may contain up to 6 stuff bytes, which have no meaning.
If I remember well, they are even not 'reserved'.
Agree, these bytes are meaningless for last TP.DT.
quoted
quoted
Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
---
 net/can/j1939/transport.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index bb5c4b8..eedaeaf 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
 static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 				 struct sk_buff *skb)
 {
+	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
 	struct j1939_priv *priv = session->priv;
 	struct j1939_sk_buff_cb *skcb, *se_skcb;
 	struct sk_buff *se_skb = NULL;
@@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 
 	skcb = j1939_skb_to_cb(skb);
 	dat = skb->data;
-	if (skb->len <= 1)
+	if (skb->len != 8) {
 		/* makes no sense */
+		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
 		goto out_session_cancel;
I think this is a situation of
"be strict on what you send, be tolerant on what you receive".

Did you find a technical reason to abort a session because the last frame didn't
bring overhead that you don't use?
No technical reason. The only reason is that SAE-J1939-82 requires responder
to abort session if any TP.DT less than 8 bytes (section A.3.4, Row 7).
Do you mean: "BAM Transport: Ensure DUT discards BAM transport when
TP.DT data packets are not correct size" ... "Verify DUT discards the
BAM transport if any TP.DT data packet has less than 8 bytes"?
Yes.
OK, then I have some problems to understand this part:
- 5.10.2.4 Connection Closure
  The “connection abort” message is not allowed to be used by responders in the
  case of a global destination (i.e. BAM).

My assumption would be: In case of broadcast transfer, multiple MCU are
receivers. If one of MCU was not able to get complete TP.DT, it should
not abort BAM for all.

So, "DUT discards the BAM transport" sounds for me as local action.
Complete TP would be dropped locally.
Yeah, you are right. With this patch receivers drop BAM transport locally
because j1939_session_cancel() only send abort message in RTS/CTS transport.

For RTS/CTS transport, SAE-J1939-82 also has similar requirements:
"RTS/CTS Transport: Data field size of Transport Data packets for RTS/CTS
(DUT as Responder)"..."Verify DUT behavior, e.g., sends a TP.CM_CTS to have
packets resent or sends a TP.Conn_Abort, when it receives TP.DT data packets
with less than 8 bytes" (section A.3.6, Row 18)
You are right. Sounds plausible. If we find some device in the field
which will need a workaround to support less than 8byte, then we will
need to add some UAPI to configure it. By default we should follow the
spec. @Kurt, do you have anything against it?

Regards,
Oleksij
-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Kurt Van Dijck <hidden>
Date: 2021-10-12 10:41:39

On Tue, 12 Oct 2021 12:21:31 +0200, Oleksij Rempel wrote:
On Mon, Oct 11, 2021 at 06:40:15PM +0800, Zhang Changzhong wrote:
quoted
On 2021/10/11 14:35, Oleksij Rempel wrote:
quoted
On Sat, Oct 09, 2021 at 04:43:56PM +0800, Zhang Changzhong wrote:
quoted
On 2021/10/8 19:00, Oleksij Rempel wrote:
quoted
On Fri, Oct 08, 2021 at 05:22:12PM +0800, Zhang Changzhong wrote:
quoted
Hi Kurt,
Sorry for the late reply.

On 2021/9/30 15:42, Kurt Van Dijck wrote:
quoted
On Thu, 30 Sep 2021 11:33:20 +0800, Zhang Changzhong wrote:
quoted
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.
SAE-j1939-21 indeed says that all TP.DT must be 8 bytes.
However, the last TP.DT may contain up to 6 stuff bytes, which have no meaning.
If I remember well, they are even not 'reserved'.
Agree, these bytes are meaningless for last TP.DT.
quoted
quoted
Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
---
 net/can/j1939/transport.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index bb5c4b8..eedaeaf 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
 static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 				 struct sk_buff *skb)
 {
+	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
 	struct j1939_priv *priv = session->priv;
 	struct j1939_sk_buff_cb *skcb, *se_skcb;
 	struct sk_buff *se_skb = NULL;
@@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 
 	skcb = j1939_skb_to_cb(skb);
 	dat = skb->data;
-	if (skb->len <= 1)
+	if (skb->len != 8) {
 		/* makes no sense */
+		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
 		goto out_session_cancel;
I think this is a situation of
"be strict on what you send, be tolerant on what you receive".

Did you find a technical reason to abort a session because the last frame didn't
bring overhead that you don't use?
No technical reason. The only reason is that SAE-J1939-82 requires responder
to abort session if any TP.DT less than 8 bytes (section A.3.4, Row 7).
Do you mean: "BAM Transport: Ensure DUT discards BAM transport when
TP.DT data packets are not correct size" ... "Verify DUT discards the
BAM transport if any TP.DT data packet has less than 8 bytes"?
Yes.
OK, then I have some problems to understand this part:
- 5.10.2.4 Connection Closure
  The “connection abort” message is not allowed to be used by responders in the
  case of a global destination (i.e. BAM).

My assumption would be: In case of broadcast transfer, multiple MCU are
receivers. If one of MCU was not able to get complete TP.DT, it should
not abort BAM for all.

So, "DUT discards the BAM transport" sounds for me as local action.
Complete TP would be dropped locally.
Yeah, you are right. With this patch receivers drop BAM transport locally
because j1939_session_cancel() only send abort message in RTS/CTS transport.

For RTS/CTS transport, SAE-J1939-82 also has similar requirements:
"RTS/CTS Transport: Data field size of Transport Data packets for RTS/CTS
(DUT as Responder)"..."Verify DUT behavior, e.g., sends a TP.CM_CTS to have
packets resent or sends a TP.Conn_Abort, when it receives TP.DT data packets
with less than 8 bytes" (section A.3.6, Row 18)
You are right. Sounds plausible. If we find some device in the field
which will need a workaround to support less than 8byte, then we will
need to add some UAPI to configure it. By default we should follow the
spec. @Kurt, do you have anything against it?
Zhang Changzhong suggested that this is part of compliance testing nowadays.
That obsoletes all technical arguments, and you have no choice than to adapt.

Kurt

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Oleksij Rempel <o.rempel@pengutronix.de>
Date: 2021-10-12 11:10:13

On Thu, Sep 30, 2021 at 11:33:20AM +0800, Zhang Changzhong wrote:
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.

Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
Acked-by: Oleksij Rempel <o.rempel@pengutronix.de>

Thank you!
quoted hunk
---
 net/can/j1939/transport.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index bb5c4b8..eedaeaf 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
 static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 				 struct sk_buff *skb)
 {
+	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
 	struct j1939_priv *priv = session->priv;
 	struct j1939_sk_buff_cb *skcb, *se_skcb;
 	struct sk_buff *se_skb = NULL;
@@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 
 	skcb = j1939_skb_to_cb(skb);
 	dat = skb->data;
-	if (skb->len <= 1)
+	if (skb->len != 8) {
 		/* makes no sense */
+		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
 		goto out_session_cancel;
+	}
 
 	switch (session->last_cmd) {
 	case 0xff:
@@ -1904,7 +1907,7 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
  out_session_cancel:
 	kfree_skb(se_skb);
 	j1939_session_timers_cancel(session);
-	j1939_session_cancel(session, J1939_XTP_ABORT_FAULT);
+	j1939_session_cancel(session, abort);
 	j1939_session_put(session);
 }
 
-- 
2.9.5

-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

From: Marc Kleine-Budde <mkl@pengutronix.de>
Date: 2021-10-17 10:34:59

On 30.09.2021 11:33:20, Zhang Changzhong wrote:
According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
cancel session when receive unexpected TP.DT message.

Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
Applied to linux-can/testing, added stable on Cc.

Thanks,
Marc

-- 
Pengutronix e.K.                 | Marc Kleine-Budde           |
Embedded Linux                   | https://www.pengutronix.de  |
Vertretung West/Dortmund         | Phone: +49-231-2826-924     |
Amtsgericht Hildesheim, HRA 2686 | Fax:   +49-5121-206917-5555 |
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help