# Re: \[PATCH net\] net: mscc: ocelot: allow forwarding from bridge ports to the tag\_8021q CPU port

- From: patchwork-bot+netdevbpf@kernel.org
- Date: 2021-08-18 22:40:11 
- List: netdev
- Page: https://ratatoskr.run/netdev/2021/08/11209678
- Thread: https://ratatoskr.run/netdev/2021/08/11209532/t.md

```text
Hello:

This patch was applied to netdev/net.git (refs/heads/master):

On Tue, 17 Aug 2021 19:04:25 +0300 you wrote:
> Currently we are unable to ping a bridge on top of a felix switch which
> uses the ocelot-8021q tagger. The packets are dropped on the ingress of
> the user port and the 'drop_local' counter increments (the counter which
> denotes drops due to no valid destinations).
> 
> Dumping the PGID tables, it becomes clear that the PGID_SRC of the user
> port is zero, so it has no valid destinations.
> 
> [...]

Here is the summary with links:
  - [net] net: mscc: ocelot: allow forwarding from bridge ports to the tag_8021q CPU port
    https://git.kernel.org/netdev/net/c/c1930148a394

You are awesome, thank you!
--
Deet-doot-dot, I am a bot.
https://korg.docs.kernel.org/patchwork/pwbot.html


```