Add initial cable testing support.
This PHY needs only 100usec for this test and it is recommended to run it
before the link is up. For now, provide at least ethtool support, so it
can be tested by more developers.
This patch was tested with TJA1102 PHY with following results:
- No cable, is detected as open
- 1m cable, with no connected other end and detected as open
- a 40m cable (out of spec, max lenght should be 15m) is detected as OK.
Current patch do not provide polarity test support. This test would
indicate not proper wire connection, where "+" wire of main phy is
connected to the "-" wire of the link partner.
Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>
---
drivers/net/phy/nxp-tja11xx.c | 106 +++++++++++++++++++++++++++++++++-
1 file changed, 105 insertions(+), 1 deletion(-)
@@ -111,6 +118,11 @@ static int tja11xx_enable_link_control(struct phy_device *phydev)returnphy_set_bits(phydev,MII_ECTRL,MII_ECTRL_LINK_CONTROL);}+staticinttja11xx_disable_link_control(structphy_device*phydev)+{+returnphy_clear_bits(phydev,MII_ECTRL,MII_ECTRL_LINK_CONTROL);+}+staticinttja11xx_wakeup(structphy_device*phydev){intret;
@@ -536,6 +548,93 @@ static int tja11xx_config_intr(struct phy_device *phydev)returnphy_write(phydev,MII_INTEN,value);}+staticinttja11xx_cable_test_start(structphy_device*phydev)+{+intret;++ret=phy_clear_bits(phydev,MII_COMMCFG,MII_COMMCFG_AUTO_OP);+if(ret)+returnret;++ret=tja11xx_wakeup(phydev);+if(ret<0)+returnret;++ret=tja11xx_disable_link_control(phydev);+if(ret<0)+returnret;++returnphy_set_bits(phydev,MII_ECTRL,MII_ECTRL_CABLE_TEST);+}++/*+*|BI_DA+|BI_DA-|Result+*|open|open|open+*|+shortto-|-shortto+|short+*|shorttoVdd|open|open+*|open|shottoVdd|open+*|shorttoVdd|shorttoVdd|short+*|shottoGND|open|open+*|open|shottoGND|open+*|shorttoGND|shottoGND|short+*|connectedtoactivelinkpartner(master)|shotandopen+*/+staticinttja11xx_cable_test_report_trans(u32result)+{+u32mask=MII_EXTSTAT_SHORT_DETECT|MII_EXTSTAT_OPEN_DETECT;++if((result&mask)==mask){+/* connected to active link partner (master) */+returnETHTOOL_A_CABLE_RESULT_CODE_UNSPEC;+}elseif((result&mask)==0){+returnETHTOOL_A_CABLE_RESULT_CODE_OK;+}elseif(result&MII_EXTSTAT_SHORT_DETECT){+returnETHTOOL_A_CABLE_RESULT_CODE_SAME_SHORT;+}elseif(result&MII_EXTSTAT_OPEN_DETECT){+returnETHTOOL_A_CABLE_RESULT_CODE_OPEN;+}else{+returnETHTOOL_A_CABLE_RESULT_CODE_UNSPEC;+}+}++staticinttja11xx_cable_test_report(structphy_device*phydev)+{+intret;++ret=phy_read(phydev,MII_EXTSTAT);+if(ret<0)+returnret;++ethnl_cable_test_result(phydev,ETHTOOL_A_CABLE_PAIR_A,+tja11xx_cable_test_report_trans(ret));++return0;+}++staticinttja11xx_cable_test_get_status(structphy_device*phydev,+bool*finished)+{+intret;++*finished=false;++ret=phy_read(phydev,MII_ECTRL);+if(ret<0)+returnret;++if(!(ret&MII_ECTRL_CABLE_TEST)){+*finished=true;++ret=phy_set_bits(phydev,MII_COMMCFG,MII_COMMCFG_AUTO_OP);+if(ret)+returnret;++returntja11xx_cable_test_report(phydev);+}++return0;+}+staticstructphy_drivertja11xx_driver[]={{PHY_ID_MATCH_MODEL(PHY_ID_TJA1100),
@@ -587,10 +687,12 @@ static struct phy_driver tja11xx_driver[] = {.get_stats=tja11xx_get_stats,.ack_interrupt=tja11xx_ack_interrupt,.config_intr=tja11xx_config_intr,-+.cable_test_start=tja11xx_cable_test_start,+.cable_test_get_status=tja11xx_cable_test_get_status,},{.name="NXP TJA1102 Port 1",.features=PHY_BASIC_T1_FEATURES,+.flags=PHY_POLL_CABLE_TEST,/* currently no probe for Port 1 is need */.soft_reset=tja11xx_soft_reset,.config_aneg=tja11xx_config_aneg,
From: Andrew Lunn <andrew@lunn.ch> Date: 2020-05-13 13:39:41
On Wed, May 13, 2020 at 02:34:40PM +0200, Oleksij Rempel wrote:
quoted hunk
Add initial cable testing support.
This PHY needs only 100usec for this test and it is recommended to run it
before the link is up. For now, provide at least ethtool support, so it
can be tested by more developers.
This patch was tested with TJA1102 PHY with following results:
- No cable, is detected as open
- 1m cable, with no connected other end and detected as open
- a 40m cable (out of spec, max lenght should be 15m) is detected as OK.
Current patch do not provide polarity test support. This test would
indicate not proper wire connection, where "+" wire of main phy is
connected to the "-" wire of the link partner.
Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>
---
drivers/net/phy/nxp-tja11xx.c | 106 +++++++++++++++++++++++++++++++++-
1 file changed, 105 insertions(+), 1 deletion(-)
Do these registers all conform to the standard? Can we pull this code
out into a library which all standards conformant PHY drivers can use?
The code itself looks O.K.
Andrew
On Wed, May 13, 2020 at 03:39:25PM +0200, Andrew Lunn wrote:
On Wed, May 13, 2020 at 02:34:40PM +0200, Oleksij Rempel wrote:
quoted
Add initial cable testing support.
This PHY needs only 100usec for this test and it is recommended to run it
before the link is up. For now, provide at least ethtool support, so it
can be tested by more developers.
This patch was tested with TJA1102 PHY with following results:
- No cable, is detected as open
- 1m cable, with no connected other end and detected as open
- a 40m cable (out of spec, max lenght should be 15m) is detected as OK.
Current patch do not provide polarity test support. This test would
indicate not proper wire connection, where "+" wire of main phy is
connected to the "-" wire of the link partner.
Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>
---
drivers/net/phy/nxp-tja11xx.c | 106 +++++++++++++++++++++++++++++++++-
1 file changed, 105 insertions(+), 1 deletion(-)
Do these registers all conform to the standard? Can we pull this code
out into a library which all standards conformant PHY drivers can use?
According to opensig, this functionality should be present on all new T1 PHYs.
But the register/bit layout is no specified as standard. At least I was not able
to find it. I assume, current layout is TJA11xx specific.
The code itself looks O.K.
What would be the best place to do a test before the link is getting up?
Can it be done in the phy core, or it should be done in the PHY driver?
So far, no action except of logging these errors is needed.
--
Pengutronix e.K. | |
Steuerwalder Str. 21 | http://www.pengutronix.de/ |
31137 Hildesheim, Germany | Phone: +49-5121-206917-0 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |
From: Andrew Lunn <andrew@lunn.ch> Date: 2020-05-13 18:01:49
What would be the best place to do a test before the link is getting up?
Can it be done in the phy core, or it should be done in the PHY driver?
So far, no action except of logging these errors is needed.
You could do it in the config_aneg callback.
A kernel log entry is not very easy to use. You might want to see how
easy it is to send a cable test result to userspace. Anything which is
interested in this information can then listen for it. All the needed
code is there, you will just need to rearrange it a bit.
Andrew
From: Andrew Lunn <andrew@lunn.ch> Date: 2020-05-13 19:31:04
quoted
Do these registers all conform to the standard? Can we pull this code
out into a library which all standards conformant PHY drivers can use?
According to opensig, this functionality should be present on all new T1 PHYs.
But the register/bit layout is no specified as standard. At least I was not able
to find it. I assume, current layout is TJA11xx specific.
O.K. then:
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Andrew
Add initial cable testing support.
This PHY needs only 100usec for this test and it is recommended to run it
before the link is up. For now, provide at least ethtool support, so it
can be tested by more developers.
This patch was tested with TJA1102 PHY with following results:
- No cable, is detected as open
- 1m cable, with no connected other end and detected as open
- a 40m cable (out of spec, max lenght should be 15m) is detected as OK.
Current patch do not provide polarity test support. This test would
indicate not proper wire connection, where "+" wire of main phy is
connected to the "-" wire of the link partner.
Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>
Add initial cable testing support.
This PHY needs only 100usec for this test and it is recommended to run it
before the link is up. For now, provide at least ethtool support, so it
can be tested by more developers.
This patch was tested with TJA1102 PHY with following results:
- No cable, is detected as open
- 1m cable, with no connected other end and detected as open
- a 40m cable (out of spec, max lenght should be 15m) is detected as OK.
Current patch do not provide polarity test support. This test would
indicate not proper wire connection, where "+" wire of main phy is
connected to the "-" wire of the link partner.
Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>
On Wed, May 13, 2020 at 08:01:40PM +0200, Andrew Lunn wrote:
quoted
What would be the best place to do a test before the link is getting up?
Can it be done in the phy core, or it should be done in the PHY driver?
So far, no action except of logging these errors is needed.
You could do it in the config_aneg callback.
In this case I get two test cycles if the test was requested from user
space: from .cable_test_get_status and from .config_aneg
A kernel log entry is not very easy to use. You might want to see how
easy it is to send a cable test result to userspace. Anything which is
interested in this information can then listen for it. All the needed
code is there, you will just need to rearrange it a bit.
Indeed. I discovered" ethtool --monitor" for me. And the code is some
thing like this:
ethnl_cable_test_alloc(phydev);
phydev->drv->cable_test_start(phydev);
usleep_range(100, 200);
phydev->drv->cable_test_get_status(phydev, &finished);
if (finished)
ethnl_cable_test_finished(phydev);
Beside, what do you think about new result codes:
ETHTOOL_A_CABLE_RESULT_CODE_POLARITY - if cable polarity is wrong (-
connected to +)
ETHTOOL_A_CABLE_RESULT_CODE_ACTIVE_PARTNER - the link partner is active.
The TJA1102 is able to detect it if partner link is master.
Regards,
Oleksij
--
Pengutronix e.K. | |
Steuerwalder Str. 21 | http://www.pengutronix.de/ |
31137 Hildesheim, Germany | Phone: +49-5121-206917-0 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |
From: Andrew Lunn <andrew@lunn.ch> Date: 2020-05-14 13:38:29
On Thu, May 14, 2020 at 02:09:59PM +0200, Oleksij Rempel wrote:
On Wed, May 13, 2020 at 08:01:40PM +0200, Andrew Lunn wrote:
quoted
quoted
What would be the best place to do a test before the link is getting up?
Can it be done in the phy core, or it should be done in the PHY driver?
So far, no action except of logging these errors is needed.
You could do it in the config_aneg callback.
In this case I get two test cycles if the test was requested from user
space: from .cable_test_get_status and from .config_aneg
Oh yes. Forgot about the restore after the test completes.
When do you want to run the test? When the interface is
administratively configured up, or when the link actually goes up?
You could do it in read_status(), when the link changes status.
quoted
A kernel log entry is not very easy to use. You might want to see how
easy it is to send a cable test result to userspace. Anything which is
interested in this information can then listen for it. All the needed
code is there, you will just need to rearrange it a bit.
Indeed. I discovered" ethtool --monitor" for me. And the code is some
thing like this:
ethnl_cable_test_alloc(phydev);
phydev->drv->cable_test_start(phydev);
usleep_range(100, 200);
phydev->drv->cable_test_get_status(phydev, &finished);
if (finished)
ethnl_cable_test_finished(phydev);
Yes, something like that.
Beside, what do you think about new result codes:
ETHTOOL_A_CABLE_RESULT_CODE_POLARITY - if cable polarity is wrong (-
connected to +)
Polarity should be a whole new nested pair property, not a status
extension. I think most PHYs are happy to work with the polarity
swapped. So we don't want it to sounds like an error. So status should
be OK and then the polarity property should then indicate it i
swapped. And you can only detected swapped polarity when the link is
up. So in most cases, you would not even include the properties, since
cable tests is normally performed on a down'ed link.
ETHTOOL_A_CABLE_RESULT_CODE_ACTIVE_PARTNER - the link partner is active.
The TJA1102 is able to detect it if partner link is master.
master is not a cable diagnostics issue. This is a configuration
issue.
Andrew
From: Christian Herber <hidden> Date: 2020-05-14 15:47:21
Hi Andrew,
On Wed, May 13, 2020 at 03:39:00PM +0200, Andrew Lunn wrote:
quoted
On Thu, May 14, 2020 at 02:09:59PM +0200, Oleksij Rempel wrote:
ETHTOOL_A_CABLE_RESULT_CODE_ACTIVE_PARTNER - the link partner is active.
The TJA1102 is able to detect it if partner link is master.
master is not a cable diagnostics issue. This is a configuration
issue.
Master is very relevant for cable diagnostics, as a cable measurement should not be done with an active link partner on the other end (i.e. a PHY in master mode trying to train the link).
So if the measurement detects an active link partner disturbing the measurement, it is important to report this to the user.
Christian
From: Andrew Lunn <andrew@lunn.ch> Date: 2020-05-14 16:01:59
On Thu, May 14, 2020 at 03:47:16PM +0000, Christian Herber wrote:
Hi Andrew,
quoted
On Wed, May 13, 2020 at 03:39:00PM +0200, Andrew Lunn wrote:
quoted
On Thu, May 14, 2020 at 02:09:59PM +0200, Oleksij Rempel wrote:
ETHTOOL_A_CABLE_RESULT_CODE_ACTIVE_PARTNER - the link partner is active.
The TJA1102 is able to detect it if partner link is master.
master is not a cable diagnostics issue. This is a configuration
issue.
Master is very relevant for cable diagnostics, as a cable
measurement should not be done with an active link partner on the
other end (i.e. a PHY in master mode trying to train the link).
So if the measurement detects an active link partner disturbing the
measurement, it is important to report this to the user.
So with 'normal' PHYs, we use autoneg to make the link go quiet. But
you don't have autoneg.
If there is no way to force the link quiet, then
ETHTOOL_A_CABLE_RESULT_CODE_ACTIVE_PARTNER makes sense. But we need to
keep the meaning generic. I don't want it to mean a T1 PHY with an
active master peer. It should be usable for any reason the link cannot
be made to go quiet.
Andrew
On Thu, May 14, 2020 at 06:01:52PM +0200, Andrew Lunn wrote:
On Thu, May 14, 2020 at 03:47:16PM +0000, Christian Herber wrote:
quoted
Hi Andrew,
quoted
On Wed, May 13, 2020 at 03:39:00PM +0200, Andrew Lunn wrote:
quoted
On Thu, May 14, 2020 at 02:09:59PM +0200, Oleksij Rempel wrote:
ETHTOOL_A_CABLE_RESULT_CODE_ACTIVE_PARTNER - the link partner is active.
The TJA1102 is able to detect it if partner link is master.
master is not a cable diagnostics issue. This is a configuration
issue.
quoted
Master is very relevant for cable diagnostics, as a cable
measurement should not be done with an active link partner on the
other end (i.e. a PHY in master mode trying to train the link).
quoted
So if the measurement detects an active link partner disturbing the
measurement, it is important to report this to the user.
So with 'normal' PHYs, we use autoneg to make the link go quiet. But
you don't have autoneg.
If there is no way to force the link quiet, then
ETHTOOL_A_CABLE_RESULT_CODE_ACTIVE_PARTNER makes sense. But we need to
keep the meaning generic. I don't want it to mean a T1 PHY with an
active master peer. It should be usable for any reason the link cannot
be made to go quiet.
It looks for me, like AT803X_CDT_STATUS_STAT_FAIL has the same reason as
ACTIVE PERTNER (Master) on TJA11xx.
What kind of meaning, naming would be generic?
--
Pengutronix e.K. | |
Steuerwalder Str. 21 | http://www.pengutronix.de/ |
31137 Hildesheim, Germany | Phone: +49-5121-206917-0 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |