# Re: \[PATCH v2 net-next 10/10\] net: bridge: implement auto-normalization of MTU for hardware datapath

- From: Vladimir Oltean \<olteanv@gmail.com\>
- Date: 2020-03-26 12:18:34 
- List: netdev
- Page: https://ratatoskr.run/netdev/2020/03/11164818
- Thread: https://ratatoskr.run/netdev/2020/03/11164638/t.md

```text
On Thu, 26 Mar 2020 at 14:06, Nikolay Aleksandrov
[ref] wrote:
>
> On 26/03/2020 13:35, Ido Schimmel wrote:
> > On Thu, Mar 26, 2020 at 12:25:20PM +0200, Vladimir Oltean wrote:
> >> Hi Ido,
> >>
> >> On Thu, 26 Mar 2020 at 12:17, Ido Schimmel [ref] wrote:
> >>>
[snip]
> >
> > I think you should be more explicit about it. Did you consider listening
> > to 'NETDEV_PRECHANGEMTU' notifications in relevant drivers and vetoing
> > unsupported configurations with an appropriate extack message? If you
> > can't veto (in order not to break user space), you can still emit an
> > extack message.
> >
>
> +1, this sounds more appropriate IMO
>

And what does vetoing gain me exactly? The practical inability to
change the MTU of any interface that is already bridged and applies
length check on RX?
```