Re: [PATCH net 2/2] net: usb: aqc111: Support for thermal throttling feature

From: Igor Russkikh <hidden>
Date: 2018-12-12 19:34:00
Also in: linux-usb

Hi Andrew,
quoted
When the PHY's temparature is back to normal (low threshold, it is
85 degrees) it restores user/default link speed settings.
Hi Igor

Please could you also export the temperature using HWMON. The Marvell
PHY drivers are good examples.

I also have a patch for driver/net/phy/aquantia.c which adds HWMON
support to that PHY.
We actually have almost ready patches to submit hwmon support separately
for both AQC USB and AQC PCI MAC drivers.
Will do that in near time.
quoted
+	if (aqc111_data->thermal_throttling)
+		speed = SPEED_100;
+
That is a big jump. Do you need to cool is down quickly, or would
1Gbps be sufficient? I think as a user, i would prefer it ping-pongs
between 5G and 1G, not 5G and 100M.
In case overheat happens that really means something bad is happening outside,
or heatsink is bad/detached. I'll consult our HW team once again, but 100M was
the original request from our phy/hw team. It seems it really much less on power and
1G may not be enough.
quoted
 	if (autoneg == AUTONEG_ENABLE) {
 		switch (speed) {
 		case SPEED_5000:
It looks like this only works when auto-neg is enabled. If i've fixed
configured it i don't think this works?
Looks you are right, will check this.

quoted
+	if (aqc111_data->thermal_throttling &&
+	    temperature <= AQ_NORMAL_TEMP_THRESHOLD) {
+		netdev_info(dev->net, "The temperature is back to normal(%u)",
+			    AQ_NORMAL_TEMP_THRESHOLD / 100);
How often do you see these messages? I'm wondering if they need to be
rate limited?
In worst case that will be at least limited by link down/up internal,
which in case of 5G normally takes 3-5secs.
quoted
+	if (!aqc111_data->thermal_throttling &&
+	    temperature >= AQ_CRITICAL_TEMP_THRESHOLD) {
Should there be some hysteresis in here? In fact, if temperature is
AQ_CRITICAL_TEMP_THRESHOLD it is both back to normal, and throttled at
the same time!
NORMAL_TEMP and CRITICAL_TEMP values are actually a hysteresis.
In cool down case only after TEMP_NORMAL temperature link will be flipped back again.
quoted
+		netdev_warn(dev->net, "Critical temperature(%u) is reached",
+			    AQ_CRITICAL_TEMP_THRESHOLD / 100);
+		aqc111_data->thermal_throttling = 1;
+		reset_speed = 1;
update_speed might be a better name, since you are not always
resetting it.
Agreed.

Regards,
  Igor