In the current flow, when you take down a physical device that has
VLANs configured on it, the NETDEV_GOING_DOWN notification will be
sent too late, i.e., no data can be sent to the wire anymore.
static int __dev_close_many(struct list_head *head)
{
...
list_for_each_entry(dev, head, unreg_list) {
call_netdevice_notifiers(NETDEV_GOING_DOWN, dev);
...
}
...
list_for_each_entry(dev, head, unreg_list) {
if (ops->ndo_stop)
ops->ndo_stop(dev);
}
...
}
static int dev_close_many(struct list_head *head)
{
...
__dev_close_many(head);
list_for_each_entry(dev, head, unreg_list) {
rtmsg_ifinfo(RTM_NEWLINK, dev, IFF_UP|IFF_RUNNING);
call_netdevice_notifiers(NETDEV_DOWN, dev);
}
}
In a setup like this: eth0 with VLANs 2, 3 the flow would be:
eth0 - NETDEV_GOING_DOWN
ndo_stop is called on the device
eth0.2 - NETDEV_GOING_DOWN
eth0.2 - NETDEV_DOWN
eth0.3 - NETDEV_GOING_DOWN
eth0.3 - NETDEV_DOWN
eth0 - NETDEV_DOWN
If instead NETDEV_GOING_DOWN is processed, the flow would be:
eth0.2 - NETDEV_GOING_DOWN
eth0.2 - NETDEV_DOWN
eth0.3 - NETDEV_GOING_DOWN
eth0.3 - NETDEV_DOWN
eth0 - NETDEV_GOING_DOWN
eth0 - NETDEV_DOWN
ndo_stop is called on the device
Signed-off-by: Eldad Zack <redacted>
---
net/8021q/vlan.c | 6 ++++++
1 file changed, 6 insertions(+)
@@ -402,6 +402,12 @@ static int vlan_device_event(struct notifier_block *unused, unsigned long event,break;+caseNETDEV_GOING_DOWN:/* NETDEV_DOWN */+/* If the parent device is going down it will call ndo_stop after+*itsendsoutNETDEV_GOING_DOWNbutbeforesendingoutNETDEV_DOWN,+*Theeffectofwhichis,thatnodatacanbesentanymore+*bythetimetheVLANdevicesendsoutitsNETDEV_GOING_DOWN.+*/caseNETDEV_DOWN:/* Put all VLANs for this dev in the down state too. */for(i=0;i<VLAN_N_VID;i++){
In the current flow, when you take down a physical device that has
VLANs configured on it, the NETDEV_GOING_DOWN notification will be
sent too late, i.e., no data can be sent to the wire anymore.
Why do you need to send data? Any queued up data should be purged not
sent.
In the current flow, when you take down a physical device that has
VLANs configured on it, the NETDEV_GOING_DOWN notification will be
sent too late, i.e., no data can be sent to the wire anymore.
Why do you need to send data? Any queued up data should be purged not
sent.
In case a certain protocol needs to send a "dying gasp" packet, when you
administrativly shutdown the port (which is also what happens when you
restart the machine).
I'm working on an implementation of such protocol (LLDP) on my free
time. The specification says that it should send a (compact) shutdown
message, with the TTL field set to zero, so that other stations are informed
of the shutdown - and it works fine with the main interface, but not with
VLANs, since the notifier is called too late.
With that small change it works as well.
Another use for it would be the Ethernet CFM, which has a similar
requirement.
On the other hand, I might've missed something. Is there a better way to
be informed of a shutdown than listening for the GOING_DOWN
event, so the frame can be sent to the wire when it's appropriate?
Eldad
In case a certain protocol needs to send a "dying gasp" packet, when you
administrativly shutdown the port (which is also what happens when you
restart the machine).
No in tree users have this requirement, therefore your patch is
inappropriate.
In case a certain protocol needs to send a "dying gasp" packet, when you
administrativly shutdown the port (which is also what happens when you
restart the machine).
No in tree users have this requirement, therefore your patch is
inappropriate.
You are right in that, that no in tree users have this requirement
(yet), but in the same time it doesn't harm any existing code.
Don't you agree that it's the right order to do the notifications?
And if so, isn't that enough, considering that there are no side
effects and it's a tiny change?
Eldad
In case a certain protocol needs to send a "dying gasp" packet, when you
administrativly shutdown the port (which is also what happens when you
restart the machine).
No in tree users have this requirement, therefore your patch is
inappropriate.
You are right in that, that no in tree users have this requirement
(yet), but in the same time it doesn't harm any existing code.
Don't you agree that it's the right order to do the notifications?
It's not an issue that matters upstream, so I simply do not care.
When you, or someone else, submits code that needs this facility
then we can talk about it.
Otherwise it's just a waste of our time.
From: Eldad Zack <redacted>
Date: Wed, 30 May 2012 23:47:32 +0200 (CEST)
It's not an issue that matters upstream, so I simply do not care.
When you, or someone else, submits code that needs this facility
then we can talk about it.
Otherwise it's just a waste of our time.
I understand that. I thought it was better to send unrelated
patches earlier.
Thanks for the review!
Eldad