[PATCH v2] powerpc/eeh: Don't check RTAS token to get PE addr
From: Gavin Shan <hidden>
Date: 2013-06-06 00:26:02
Subsystem:
linux for powerpc (32-bit and 64-bit), pci enhanced error handling (eeh) for powerpc, the rest · Maintainers:
Madhavan Srinivasan, Mahesh J Salgaonkar, Linus Torvalds
RTAS token "ibm,get-config-addr-info" or ibm,get-config-addr-info2"
are used to retrieve the PE address according to PCI address, which
made up of domain/bus/slot/function. If we don't have those 2 tokens,
the domain/bus/slot/function would be used as the address for EEH
RTAS operations. Some older f/w might not have those 2 tokens and
that blocks the EEH functionality to be initialized. It was introduced
by commit e2af155c ("powerpc/eeh: pseries platform EEH initialization").
The patch skips the check on those 2 tokens so we can bring up EEH
functionality successfully. And domain/bus/slot/function will be
used as address for EEH RTAS operations.
Cc: <redacted> # v3.4+
Reported-by: Robert Knight <redacted>
Signed-off-by: Gavin Shan <redacted>
Tested-by: Robert Knight <redacted>
---
arch/powerpc/platforms/pseries/eeh_pseries.c | 12 +++++-------
1 files changed, 5 insertions(+), 7 deletions(-)
diff --git a/arch/powerpc/platforms/pseries/eeh_pseries.c b/arch/powerpc/platforms/pseries/eeh_pseries.c
index 19506f9..b456b15 100644
--- a/arch/powerpc/platforms/pseries/eeh_pseries.c
+++ b/arch/powerpc/platforms/pseries/eeh_pseries.c@@ -83,7 +83,11 @@ static int pseries_eeh_init(void) ibm_configure_pe = rtas_token("ibm,configure-pe"); ibm_configure_bridge = rtas_token("ibm,configure-bridge"); - /* necessary sanity check */ + /* + * Necessary sanity check. We needn't check "get-config-addr-info" + * and its variant since the old firmware probably support address + * of domain/bus/slot/function for EEH RTAS operations. + */ if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE) { pr_warning("%s: RTAS service <ibm,set-eeh-option> invalid\n", __func__);
@@ -102,12 +106,6 @@ static int pseries_eeh_init(void) pr_warning("%s: RTAS service <ibm,slot-error-detail> invalid\n", __func__); return -EINVAL; - } else if (ibm_get_config_addr_info2 == RTAS_UNKNOWN_SERVICE && - ibm_get_config_addr_info == RTAS_UNKNOWN_SERVICE) { - pr_warning("%s: RTAS service <ibm,get-config-addr-info2> and " - "<ibm,get-config-addr-info> invalid\n", - __func__); - return -EINVAL; } else if (ibm_configure_pe == RTAS_UNKNOWN_SERVICE && ibm_configure_bridge == RTAS_UNKNOWN_SERVICE) { pr_warning("%s: RTAS service <ibm,configure-pe> and "
--
1.7.5.4