RE: COP Status 0x21

2 messages, 2 authors, 2005-08-25 · open the first message on its own page

RE: COP Status 0x21

From: Andrew Williams <hidden>
Date: 2005-08-25 15:30:11

<insert favorite curses here>

  Spend 6 hours searching, draft an email to the list, and solve=20
problem 20 minutes later. Compared my BDI to a co-workers and=20
and discovered that although we had the same firmware, we didn't have=20
the same "Logic" version in the device. Reflashed and I can=20
now read the PVR correctly.

  Sorry to waste everyone's time on this.

Andrew

  =20
-----Original Message-----
From: linuxppc-embedded-bounces@ozlabs.org=20
[mailto:linuxppc-embedded-bounces@ozlabs.org] On Behalf Of=20
Williams, Andrew [CAR:9D30:EXCH]
Sent: August 25, 2005 10:38 AM
To: linuxppc-embedded@ozlabs.org
Subject: COP Status 0x21
=20
=20
Hello List..
  (hope this is considered "on" topic)
=20
   Situation: New hardware (mcp8347)
              BDI connected, but unable to read PVR
              Prior to the READ I see a "COP status is 0x21"
       =20
   Q. What does a status of 0x21 mean?=20
=20
   Q. I've searched online for some type of a reference to the=20
      COP interface to no avail. Can anyone direct me to=20
      a technical reference?=20
=20
=20
Thanks,
Andrew
=20
-- BDI Config [TARGET] section --
[TARGET]
CPUTYPE     8349                        ;the CPU type
JTAGCLOCK   0                           ;use 16 MHz JTAG clock
BOOTADDR    0xfff00100                  ;boot address used=20
for start-up
break
POWERUP     2000                        ;start delay after power-up
detected in ms
WAKEUP      800                         ;give reset time to complete
STARTUP     RESET                       ;halt immediatelly at the boot
vector
BREAKMODE   HARD                        ;SOFT or HARD, HARD uses PPC
hardware breakpoint
STEPMODE    HWBP                        ;TRACE or HWBP, HWBP uses a
hardware breakpoint
=20
=20
-- BDI Debug Output --
- TARGET: waiting for target Vcc
- TARGET: processing power-up delay
- TARGET: processing user reset request
- BDI asserts HRESET
- Reset JTAG controller passed
- Bypass check: 0x00000001 =3D> 0x00000001
- Bypass check: 0x00000001 =3D> 0x00000001
- JTAG exists check passed
- COP status is 0x21
- Check running state passed
- BDI scans COP freeze command
- BDI removes HRESET
- Target PVR is 0x00000000
- This PVR is not supported
- TARGET: Target PVR is 0x00000000
*** TARGET: resetting target failed
# PPC: This target is not supported
- TARGET: target will be restarted in 10 sec=20
_______________________________________________
Linuxppc-embedded mailing list
Linuxppc-embedded@ozlabs.org=20
https://ozlabs.org/mailman/listinfo/linuxppc-> embedded
=20
=20

Re: COP Status 0x21

From: Grant Likely <hidden>
Date: 2005-08-25 16:22:17

On Thu, Aug 25, 2005 at 11:19:31AM -0400, Andrew Williams wrote:
<insert favorite curses here>

  Spend 6 hours searching, draft an email to the list, and solve 
problem 20 minutes later. Compared my BDI to a co-workers and 
and discovered that although we had the same firmware, we didn't have 
the same "Logic" version in the device. Reflashed and I can 
now read the PVR correctly.

  Sorry to waste everyone's time on this.
Ah, but the next person to have this problem (should) find your post
when they search.  :)
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help