PCI Config access doesn't return correct data...
From: ashish anand <hidden>
Date: 2001-07-19 06:29:43
Hi all, I found a strange behaviour of pci config access on my board. my host bridge is MPC107(address map b) indirect pci config access method with config_addr and config_data ports at 0xfec00000 and 0xfee00000. I am using sandpoint+750 board and Bluecat Linux. I have a case of pci config not returning devid and vendorid correctly sometime 0x00000000 , hence the cards put in slot are not even detected , in following conditions. (card not behaving correctly are scsi aha 294xxx and 3c905b n/w card but surprisingly INTEL 82559 always behaves correctly) 1> when you boot through osloader 2> when you put your scsi or 3com card in OUTER slot only but when i put mb() in definition of pcibios_xxxx_config_xxxx in file indirect_pci.c before and after the reading and writing the pci_config_addr and pci_config_data ports everything behaves correctly. it is clear that it was a reordering problem. i want a further comment on this ,why it should happen? noteworthy point is that it only happens when you , boot through osloader + with scsi and 3com cards not intel one + only when cards are put in OUTER slots. ** Sent via the linuxppc-dev mail list. See http://lists.linuxppc.org/