I reflashed my BDI2000 (loader=1.03, firmware=1.01, logic=1.01).
Unfortunately I get the same results. I will contact Abatron. Perhaps
there is a bug in this version of the command parser.
Thanks,
Brian
-----Original Message-----
From: Wolfgang Denk [mailto:<redacted>]
Sent: Tuesday, January 30, 2001 4:14 PM
To: Brian Kuschak
Cc: <redacted>
Subject: Re: Abatron BDI2000
In message <B25E2E5A003CD311B61E00902778AF2A0204433C@SERVER1> you wrote:
Is anyone out there using the Abatron BDI2000 to set hardware breakpoints
on
data access (on 405GP)? I'm probably just doing something dumb, but I
don't
see it. Any ideas?
Not on 405, but on 8xx / 82xx instead.
BDI>bd w 0xc019c390
# syntax is BDx [R|W]
BDI>bd w 0xc019c390
Breakpoint identification is 0
Works fine for me.
BDI>bdx w 0xc019c390
# syntax error in command
Error, "bdx" is no valid command.
BDI>bd w c019c390
# syntax error in command
Error, c0... is no valid hex number (0x... missing).
BDI>bd 0xc019c390
# syntax is BDx [R|W]
BDI>bd 0xc019c390
Breakpoint identification is 1
Works fine for me.
Um... Try re-loading the firmware.
Wolfgang Denk
--
Software Engineering: Embedded and Realtime Systems, Embedded Linux
Phone: (+49)-8142-4596-87 Fax: (+49)-8142-4596-88 Email: wd@denx.de
Visit us at Embedded Systems: Feb 14-16 2001, Nuremberg, Halle 12/K01
(with TQ Components); our presentation "Starke Zwerge: Embedded Linux
auf PowerPC-Systemen" on Thursday, Feb 15 2001, 13:30 Forum Halle 11.
** Sent via the linuxppc-embedded mail list. See http://lists.linuxppc.org/