Re: raid5 - which disk failed ?

2 messages, 2 authors, 2007-09-24 · open the first message on its own page

Re: raid5 - which disk failed ?

From: Neil Brown <hidden>
Date: 2007-09-24 02:44:23

On Monday September 24, rfu@kaneda.iguw.tuwien.ac.at wrote:
Hi,

I'm using a raid 5 with 4*400 GB PATA disks on a rather old VIA
mainboard, running centos 5.0. a few days ago the server started to
reboot or freeze occasionally, after reboot md always starts a resync
of the raid:
$ cat /proc/mdstat
Personalities : [raid6] [raid5] [raid4]
md0 : active raid5 hdh1[3] hdg1[2] hdf1[1] hde1[0]
      1172126208 blocks level 5, 64k chunk, algorithm 2 [4/4] [UUUU]
      [>....................]  resync =  0.9% (3819132/390708736) finish=366.2min speed=17603K/sec
This is normal.  If there was any write activity in the few hundred
milliseconds before a crash, you need to resync because the parity of
the stripe being written could not incorrect.
after about an hour, the server freezes again. I figured out that
about this time the following errors are reported in the messages log:

Sep 23 22:23:05 alfred kernel: end_request: I/O error, dev hde, sector 254106007
Sep 23 22:23:09 alfred kernel: hde: dma_intr: status=0x51 { DriveReady SeekComplete Error }
Sep 23 22:23:09 alfred kernel: hde: dma_intr: error=0x40 { UncorrectableError }, LBAsect=254106015, high=15, low=2447775, sector=254106015
Sep 23 22:23:09 alfred kernel: end_request: I/O error, dev hde, sector 254106015
Sep 23 22:23:14 alfred kernel: hde: dma_intr: status=0x51 { DriveReady SeekComplete Error }
Sep 23 22:23:14 alfred kernel: hde: dma_intr: error=0x40 { UncorrectableError }, LBAsect=254106023, high=15, low=2447783, sector=254106023
Sep 23 22:23:14 alfred kernel: end_request: I/O error, dev hde, sector 254106023
Sep 23 22:23:18 alfred kernel: hde: dma_intr: status=0x51 { DriveReady SeekComplete Error }
Sep 23 22:23:18 alfred kernel: hde: dma_intr: error=0x40 { UncorrectableError }, LBAsect=254106031, high=15, low=2447791, sector=254106031
Sep 23 22:23:18 alfred kernel: end_request: I/O error, dev hde, sector 254106031
Sep 23 22:23:23 alfred kernel: hde: dma_intr: status=0x51 { DriveReady SeekComplete Error }
Sep 23 22:23:23 alfred kernel: hde: dma_intr: error=0x40 { UncorrectableError }, LBAsect=254106039, high=15, low=2447799, sector=254106039
Sep 23 22:23:23 alfred kernel: end_request: I/O error, dev hde, sector 254106039
Sep 23 22:23:43 alfred kernel: hde: dma_timer_expiry: dma status == 0x21
Sep 23 22:23:53 alfred kernel: hde: DMA timeout error
Sep 23 22:23:53 alfred kernel: hde: dma timeout error: status=0x58 { DriveReady SeekComplete DataRequest }
Sep 23 22:28:40 alfred kernel:     ide2: BM-DMA at 0x7800-0x7807, BIOS settings: hde:DMA, hdf:pio
Something definitely sick there.
now there are two things that puzzle me:

1) when md starts a resync of the array, shouldn't one drive be marked
as down [_UUU] in mdstat instead of reporting it as [UUUU] ? or, the
other way round: is hde really the faulty drive ? how can I make sure
I'm removing and replacing the proper drive ?
When a drive fail, md records that failure in the metadata on the
other devices in the array.
The fact that the drive is not marked as failed after the reboot
suggests that md failed to update the metadata of the good drives.
Maybe it is the controller that is failing rather than a drive, and it
cannot write to anything at this point.
Or maybe the drive is failing, but that is badly confusing the
controller, with the same result.
Is it always hde that is reporting errors?

With PATA, it is fairly easy to make sure you have removed the correct
drive, and names don't change.  hde is the 'master' on the 3rd
channel.  Presumably the first channel of your controller card.

Just disconnect the drive you think it is, reboot, and see if hde is
still there.
2) can a faulty drive in a raid5 really crash the whole server ? maybe
it's because of the bug in the onboard promise controller that adds to
this problem (see attachment for dmesg output).
No, a faulty drive in a raid5 should not crash the whole server.  But
a bad controller card or buggy driver for the controller could.

NeilBrown

Re[2]: raid5 - which disk failed ?

From: Rainer Fuegenstein <hidden>
Date: 2007-09-24 23:05:01


NB> Or maybe the drive is failing, but that is badly confusing the
NB> controller, with the same result.
NB> Is it always hde that is reporting errors?

for now - yes; but a few months ago for a short period of time hdg and
hdh also have been reported with errors, but this went away quickly
and never occured again.

NB> With PATA, it is fairly easy to make sure you have removed the correct
NB> drive, and names don't change.  hde is the 'master' on the 3rd
NB> channel.  Presumably the first channel of your controller card.

I know; what I meant was: I'd like to make sure that I remove the one
drive that md thinks is faulty - I want to avoid removing a healthy
drive, leaving md with one broken drive and two healthy ones which
isn't good for a raid5. but in this case, hde rather certainly is the
troublemaker.

NB> No, a faulty drive in a raid5 should not crash the whole server.  But
NB> a bad controller card or buggy driver for the controller could.

this seems to be the case here. guess its time to shop for a new
server.

tnx.

------------------------------------------------------------------------------
 Rainer Fuegenstein                              rfu@kaneda.iguw.tuwien.ac.at
------------------------------------------------------------------------------
"Why are you looking into the darkness and not into the fire as we do ?", Nell
asked. "Because the darkness is where danger comes from," Peter said, "and
from the fire comes only illusion".                   (from "The Diamond Age")
------------------------------------------------------------------------------