From: Jian Dong <redacted>
Fixes coccicheck ERROR:
drivers/thermal/qcom/tsens.c:759:4-10: ERROR: missing put_device;
call of_find_device_by_node on line 715, but without a corresponding
object release within this function.
Signed-off-by: Jian Dong <redacted>
---
drivers/thermal/qcom/tsens.c | 6 ++++--
1 file changed, 4 insertions(+), 2 deletions(-)
diff --git a/drivers/thermal/qcom/tsens.c b/drivers/thermal/qcom/tsens.c
index d8ce3a6..3c4c051 100644
--- a/drivers/thermal/qcom/tsens.c
+++ b/drivers/thermal/qcom/tsens.c
@@ -755,8 +755,10 @@ int __init init_common(struct tsens_priv *priv)
for (i = VER_MAJOR; i <= VER_STEP; i++) {
priv->rf[i] = devm_regmap_field_alloc(dev, priv->srot_map,
priv->fields[i]);
- if (IS_ERR(priv->rf[i]))
- return PTR_ERR(priv->rf[i]);
+ if (IS_ERR(priv->rf[i])) {
+ ret = PTR_ERR(priv->rf[i]);
+ goto err_put_device;
+ }
}
ret = regmap_field_read(priv->rf[VER_MINOR], &ver_minor);
if (ret)--
1.9.1