[PATCH] hid: sony: Set the Sixaxis cable state correctly

Subsystems: hid core layer, the rest

STALE4355d

2 messages, 2 authors, 2014-09-01 · open the first message on its own page

[PATCH] hid: sony: Set the Sixaxis cable state correctly

From: Frank Praznik <hidden>
Date: 2014-08-29 17:12:11

Bit 3 in byte 31 of the Sixaxis report indicates whether the battery is
charging or not charging as opposed to whether or not the cable is plugged in.
As a result, when connected via USB and fully charged, the power_supply status
is wrongly reported as 'Discharging' instead of 'Full'.

Use the battery level value to set the cable state so that the power status
is reported correctly as that seems to be the only reliable way to determine the
cable status on the Sixaxis.

Signed-off-by: Frank Praznik <redacted>
---
 drivers/hid/hid-sony.c | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)
diff --git a/drivers/hid/hid-sony.c b/drivers/hid/hid-sony.c
index c372368..ecc6616 100644
--- a/drivers/hid/hid-sony.c
+++ b/drivers/hid/hid-sony.c
@@ -935,12 +935,13 @@ static void sixaxis_parse_report(struct sony_sc *sc, __u8 *rd, int size)
 	if (rd[30] >= 0xee) {
 		battery_capacity = 100;
 		battery_charging = !(rd[30] & 0x01);
+		cable_state = 1;
 	} else {
 		__u8 index = rd[30] <= 5 ? rd[30] : 5;
 		battery_capacity = sixaxis_battery_capacity[index];
 		battery_charging = 0;
+		cable_state = 0;
 	}
-	cable_state = !(rd[31] & 0x04);
 
 	spin_lock_irqsave(&sc->lock, flags);
 	sc->cable_state = cable_state;
-- 
1.9.3

Re: [PATCH] hid: sony: Set the Sixaxis cable state correctly

From: Jiri Kosina <hidden>
Date: 2014-09-01 09:21:50

On Fri, 29 Aug 2014, Frank Praznik wrote:
Bit 3 in byte 31 of the Sixaxis report indicates whether the battery is
charging or not charging as opposed to whether or not the cable is plugged in.
As a result, when connected via USB and fully charged, the power_supply status
is wrongly reported as 'Discharging' instead of 'Full'.

Use the battery level value to set the cable state so that the power status
is reported correctly as that seems to be the only reliable way to determine the
cable status on the Sixaxis.

Signed-off-by: Frank Praznik <redacted>
Applied, thanks.

-- 
Jiri Kosina
SUSE Labs