# Re: \[PATCH v7 0/6\] w1: ds2438: adding support for calibration of current measurements

- From: Greg KH \<gregkh@linuxfoundation.org\>
- Date: 2021-05-14 11:47:23 
- List: linux-doc
- Page: https://ratatoskr.run/linux-doc/2021/05/1377704
- Thread: https://ratatoskr.run/linux-doc/2021/04/6332144/t.md

```text
On Fri, Apr 16, 2021 at 07:17:33PM -0300, Luiz Sampaio wrote:
> The following patches aim to make a user able to calibrate the current
> measurement of the DS2438. This chip uses a offset register in page1, which
> is added to the current register to give the user the current measurement.
> If this value is wrong, the user will get an offset current value, even if
> the current is zero, for instance. This patch gives support for reading the
> page1 registers (including the offset register) and for writing to the
> offset register. The DS2438 datasheet shows a calibration routine, and with
> this patch, the user can do this quickly by writing the correct value to
> the offset register. This patch was tested on real hardware using a power
> supply and an electronic load.
> Please help to review this series of patches.
> 
> Best regards!
> Sampaio
> ---
> Changes in v7:
> - Build test again

Can you fix the warning in patch 6/6 that the kernel test robot found,
and resend?

thanks,

greg k-h
```