# Re: \[PATCH 08/10\] ARM: dts: Cygnus: Fix SP805 clocks

- From: Florian Fainelli \<f.fainelli@gmail.com\>
- Date: 2020-08-31 03:59:43 
- List: linux-devicetree
- Page: https://ratatoskr.run/linux-devicetree/2020/08/6087810
- Thread: https://ratatoskr.run/linux-devicetree/2020/08/6086367/t.md

```text


On 8/30/2020 8:55 PM, Florian Fainelli wrote:
> On Fri, 28 Aug 2020 14:06:00 +0100, Andre Przywara [ref] wrote:
>> The SP805 DT binding requires two clocks to be specified, but the
>> Broadcom Cygnus DT currently only specifies one clock.
>>
>> In practice, Linux would pick a clock named "apb_pclk" for the bus
>> clock, and the Linux and U-Boot SP805 driver would use the first clock
>> to derive the actual watchdog counter frequency.
>>
>> Since currently both are the very same clock, we can just double the
>> clock reference, and add the correct clock-names, to match the binding.
>>
>> Signed-off-by: Andre Przywara <andre.przywara@arm.com>
>> ---
>
> Applied to qspi-fixes, thanks!

Applied to devicetree/next actually, likewise for the next patch.
-- 
Florian
```