Re: [PATCH] ARM: dts: exynos: Use thermal fuse value for thermal zone 0 on Exynos5420
From: Anand Moon <hidden>
Date: 2017-03-06 07:29:52
Also in:
linux-arm-kernel, linux-pm, linux-samsung-soc, lkml
Hi Krzysztof, On 4 March 2017 at 13:31, Krzysztof Kozlowski [off-list ref] wrote:
On Fri, Mar 03, 2017 at 06:50:06PM -0300, Javier Martinez Canillas wrote:quoted
Hello Krzysztof, On 02/11/2017 05:14 PM, Krzysztof Kozlowski wrote:quoted
In Odroid XU3 Lite board, the temperature levels reported for thermal zone 0 were weird. In warm room: /sys/class/thermal/thermal_zone0/temp:32000 /sys/class/thermal/thermal_zone1/temp:51000 /sys/class/thermal/thermal_zone2/temp:55000 /sys/class/thermal/thermal_zone3/temp:54000 /sys/class/thermal/thermal_zone4/temp:51000 Sometimes after booting the value was even equal to ambient temperature which is highly unlikely to be a real temperature of sensor in SoC. The thermal sensor's calibration (trimming) is based on fused values. In case of the board above, the fused values are: 35, 52, 43, 58 and 43 (corresponding to each TMU device). However driver defined a minimum value for fused data as 40 and for smaller values it was using a hard-coded 55 instead. This lead to mapping data from sensor to wrong temperatures for thermal zone 0. Various vendor 3.10 trees (Hardkernel's based on Samsung LSI, Artik 10) do not impose any limits on fused values. Since we do not have any knowledge about these limits, use 0 as a minimum accepted fused value. This should essentially allow accepting any reasonable fused value thus behaving like vendor driver. The exynos5420-tmu-sensor-conf.dtsi is copied directly from existing exynso4412 with one change - the samsung,tmu_min_efuse_value. Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org> --- Testing on other Exynos542x boards is much appreciated. Especially I wonder what efuse values are there.I tested on both Exynos5422 Odroid XU4 and Exynos5800 Peach Pi boards. The temperatures levels reported for these two boards on a warm room are: Odroid XU4 # cat /sys/class/thermal/thermal_zone*/temp 50000 50000 54000 51000 48000 Peach Pi # cat /sys/class/thermal/thermal_zone*/temp 42000 44000 27000 <-- weird value for thermal zone 2 like zone 0 in your XU3 lite 45000 45000 And the efuse values for the TMU devices are: Odroid XU4 TMU0 = 45 TMU1 = 44 TMU2 = 44 TMU3 = 46 TMU3 = 46 Peach Pi TMU0 = 44 TMU1 = 46 TMU2 = 36 TMU3 = 53 TMU3 = 46 The fused value for TMU2 is < 40 so that explains the weird temperature level for thermal zone 2 in Peach. So after your patch, makes more sense: # cat /sys/class/thermal/thermal_zone*/temp 41000 42000 45000 43000 43000Great! Thanks for testing!quoted
I wonder though if 0 is the best value or if we should just lower more to cover the used e-fuse values in Exynos5 boards. But as you said, we have no knowledge about these limits...Yeah... we could set value of 10 or 20... but that would be blind shot.quoted
Reviewed-by: Javier Martinez Canillas <redacted> Tested-by: Javier Martinez Canillas <redacted>Thanks, Krzysztof
Reviewed-by: Anand Moon <redacted> Tested-by: Anand Moon <redacted> I have being trying to change the trips temperature in the dts to some higher values in order to improve the performance of the board. Here are the results under idle state and stress state. root@odroidxu4n:~# cat /sys/class/thermal/thermal_zone*/temp 58000 58000 61000 60000 56000 root@odroidxu4n:~# stress --vm 16 --vm-bytes 128M --timeout 10s stress: info: [2138] dispatching hogs: 0 cpu, 0 io, 16 vm, 0 hdd stress: info: [2138] successful run completed in 10s root@odroidxu4n:~# cat /sys/class/thermal/thermal_zone*/temp 58000 58000 61000 60000 56000 Which is too high for in idle state. Second part of my testcase is the pm-qa from linaro. [1] git://git.linaro.org/tools/pm-qa.git pm-qa# make -C thermal check I have observer in the testcase that their is use moderate heating of heat_cpu get started by the testcase but it dose not get signal to kill on exiting of the testcase. most of these testcase failed to Odroid XU4, but the same case pass on Odroid U3. I have also tested with different e-fuse values [10,20,30,40] but the results are same. Going through the source code for HK it seen to set exynos_tmu_control set more trigger level [2] https://github.com/hardkernel/linux/blob/odroidxu3-3.10.y/drivers/thermal/exynos_thermal.c#L1144 Best Regards -Anand Moon