[PATCH v4] arm64: dts: renesas: r8a7795: Move nodes which have no reg property out of bus

Subsystems: arm/risc-v/renesas architecture, the rest

STALE3175d

2 messages, 2 authors, 2017-12-07 · open the first message on its own page

[PATCH v4] arm64: dts: renesas: r8a7795: Move nodes which have no reg property out of bus

From: Simon Horman <hidden>
Date: 2017-11-30 10:25:39

Move pmu_a5[73], timer and thermal-zones nodes from soc node to root node.
The nodes that have been moved do not have any register properties and thus
shouldn't be placed on the bus.

This problem is flagged by the compiler as follows:
$ make
...
  DTC     arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb
arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property
  DTC     arch/arm64/boot/dts/renesas/r8a7795-h3ulcb.dtb
arch/arm64/boot/dts/renesas/r8a7795-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property
  DTC     arch/arm64/boot/dts/renesas/r8a7795-h3ulcb-kf.dtb
arch/arm64/boot/dts/renesas/r8a7795-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property
  DTC     arch/arm64/boot/dts/renesas/r8a7795-salvator-xs.dtb
arch/arm64/boot/dts/renesas/r8a7795-salvator-xs.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-salvator-xs.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-salvator-xs.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-salvator-xs.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property
  DTC     arch/arm64/boot/dts/renesas/r8a7795-es1-salvator-x.dtb
arch/arm64/boot/dts/renesas/r8a7795-es1-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-es1-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-es1-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-es1-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property
  DTC     arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb.dtb
arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property
  DTC     arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb-kf.dtb
arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property
arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property

Signed-off-by: Simon Horman <redacted>
---
v4
* Use interrupts-extended rather than interrupt-parent + interrupts
  in /pmu_* and /timer nodes as seems to be preferred.
v3
* Add interrupt-parent property to /pmu_* and /timer nodes as
  it is no longer inherited from the parent node
v2
* Preserve alphabetical order of nodes present in root node.

Based on renesas-devel-20171130-v4.15-rc1
---
 arch/arm64/boot/dts/renesas/r8a7795.dtsi | 138 ++++++++++++++++---------------
 1 file changed, 71 insertions(+), 67 deletions(-)
diff --git a/arch/arm64/boot/dts/renesas/r8a7795.dtsi b/arch/arm64/boot/dts/renesas/r8a7795.dtsi
index 6db4f10376a1..a851c88e1e04 100644
--- a/arch/arm64/boot/dts/renesas/r8a7795.dtsi
+++ b/arch/arm64/boot/dts/renesas/r8a7795.dtsi
@@ -184,6 +184,30 @@
 		clock-frequency = <0>;
 	};
 
+	pmu_a57 {
+		compatible = "arm,cortex-a57-pmu";
+		interrupts-extended = <&gic GIC_SPI 72 IRQ_TYPE_LEVEL_HIGH>,
+		                      <&gic GIC_SPI 73 IRQ_TYPE_LEVEL_HIGH>,
+				      <&gic GIC_SPI 74 IRQ_TYPE_LEVEL_HIGH>,
+				      <&gic GIC_SPI 75 IRQ_TYPE_LEVEL_HIGH>;
+		interrupt-affinity = <&a57_0>,
+				     <&a57_1>,
+				     <&a57_2>,
+				     <&a57_3>;
+	};
+
+	pmu_a53 {
+		compatible = "arm,cortex-a53-pmu";
+		interrupts-extended = <&gic GIC_SPI 84 IRQ_TYPE_LEVEL_HIGH>,
+				      <&gic GIC_SPI 85 IRQ_TYPE_LEVEL_HIGH>,
+				      <&gic GIC_SPI 86 IRQ_TYPE_LEVEL_HIGH>,
+				      <&gic GIC_SPI 87 IRQ_TYPE_LEVEL_HIGH>;
+		interrupt-affinity = <&a53_0>,
+				     <&a53_1>,
+				     <&a53_2>,
+				     <&a53_3>;
+	};
+
 	soc: soc {
 		compatible = "simple-bus";
 		interrupt-parent = <&gic>;
@@ -338,42 +362,6 @@
 			resets = <&cpg 905>;
 		};
 
-		pmu_a57 {
-			compatible = "arm,cortex-a57-pmu";
-			interrupts = <GIC_SPI 72 IRQ_TYPE_LEVEL_HIGH>,
-				     <GIC_SPI 73 IRQ_TYPE_LEVEL_HIGH>,
-				     <GIC_SPI 74 IRQ_TYPE_LEVEL_HIGH>,
-				     <GIC_SPI 75 IRQ_TYPE_LEVEL_HIGH>;
-			interrupt-affinity = <&a57_0>,
-					     <&a57_1>,
-					     <&a57_2>,
-					     <&a57_3>;
-		};
-
-		pmu_a53 {
-			compatible = "arm,cortex-a53-pmu";
-			interrupts = <GIC_SPI 84 IRQ_TYPE_LEVEL_HIGH>,
-				     <GIC_SPI 85 IRQ_TYPE_LEVEL_HIGH>,
-				     <GIC_SPI 86 IRQ_TYPE_LEVEL_HIGH>,
-				     <GIC_SPI 87 IRQ_TYPE_LEVEL_HIGH>;
-			interrupt-affinity = <&a53_0>,
-					     <&a53_1>,
-					     <&a53_2>,
-					     <&a53_3>;
-		};
-
-		timer {
-			compatible = "arm,armv8-timer";
-			interrupts = <GIC_PPI 13
-					(GIC_CPU_MASK_SIMPLE(8) | IRQ_TYPE_LEVEL_LOW)>,
-				     <GIC_PPI 14
-					(GIC_CPU_MASK_SIMPLE(8) | IRQ_TYPE_LEVEL_LOW)>,
-				     <GIC_PPI 11
-					(GIC_CPU_MASK_SIMPLE(8) | IRQ_TYPE_LEVEL_LOW)>,
-				     <GIC_PPI 10
-					(GIC_CPU_MASK_SIMPLE(8) | IRQ_TYPE_LEVEL_LOW)>;
-		};
-
 		cpg: clock-controller at e6150000 {
 			compatible = "renesas,r8a7795-cpg-mssr";
 			reg = <0 0xe6150000 0 0x1000>;
@@ -2331,47 +2319,63 @@
 			#thermal-sensor-cells = <1>;
 			status = "okay";
 		};
+	};
 
-		thermal-zones {
-			sensor_thermal1: sensor-thermal1 {
-				polling-delay-passive = <250>;
-				polling-delay = <1000>;
-				thermal-sensors = <&tsc 0>;
+	timer {
+		compatible = "arm,armv8-timer";
+		interrupts-extended = <&gic GIC_PPI 13
+				       (GIC_CPU_MASK_SIMPLE(8) |
+				       IRQ_TYPE_LEVEL_LOW)>,
+				      <&gic GIC_PPI 14
+				       (GIC_CPU_MASK_SIMPLE(8) |
+				       IRQ_TYPE_LEVEL_LOW)>,
+				      <&gic GIC_PPI 11
+				       (GIC_CPU_MASK_SIMPLE(8) |
+				       IRQ_TYPE_LEVEL_LOW)>,
+				      <&gic GIC_PPI 10
+				       (GIC_CPU_MASK_SIMPLE(8) |
+				       IRQ_TYPE_LEVEL_LOW)>;
+	};
 
-				trips {
-					sensor1_crit: sensor1-crit {
-						temperature = <120000>;
-						hysteresis = <2000>;
-						type = "critical";
-					};
+	thermal-zones {
+		sensor_thermal1: sensor-thermal1 {
+			polling-delay-passive = <250>;
+			polling-delay = <1000>;
+			thermal-sensors = <&tsc 0>;
+
+			trips {
+				sensor1_crit: sensor1-crit {
+					temperature = <120000>;
+					hysteresis = <2000>;
+					type = "critical";
 				};
 			};
+		};
 
-			sensor_thermal2: sensor-thermal2 {
-				polling-delay-passive = <250>;
-				polling-delay = <1000>;
-				thermal-sensors = <&tsc 1>;
+		sensor_thermal2: sensor-thermal2 {
+			polling-delay-passive = <250>;
+			polling-delay = <1000>;
+			thermal-sensors = <&tsc 1>;
 
-				trips {
-					sensor2_crit: sensor2-crit {
-						temperature = <120000>;
-						hysteresis = <2000>;
-						type = "critical";
-					};
+			trips {
+				sensor2_crit: sensor2-crit {
+					temperature = <120000>;
+					hysteresis = <2000>;
+					type = "critical";
 				};
 			};
+		};
 
-			sensor_thermal3: sensor-thermal3 {
-				polling-delay-passive = <250>;
-				polling-delay = <1000>;
-				thermal-sensors = <&tsc 2>;
+		sensor_thermal3: sensor-thermal3 {
+			polling-delay-passive = <250>;
+			polling-delay = <1000>;
+			thermal-sensors = <&tsc 2>;
 
-				trips {
-					sensor3_crit: sensor3-crit {
-						temperature = <120000>;
-						hysteresis = <2000>;
-						type = "critical";
-					};
+			trips {
+				sensor3_crit: sensor3-crit {
+					temperature = <120000>;
+					hysteresis = <2000>;
+					type = "critical";
 				};
 			};
 		};
-- 
2.11.0

Re: [PATCH v4] arm64: dts: renesas: r8a7795: Move nodes which have no reg property out of bus

From: Simon Horman <horms@verge.net.au>
Date: 2017-12-07 10:00:45

On Thu, Nov 30, 2017 at 11:25:39AM +0100, Simon Horman wrote:
Move pmu_a5[73], timer and thermal-zones nodes from soc node to root node.
The nodes that have been moved do not have any register properties and thus
shouldn't be placed on the bus.

This problem is flagged by the compiler as follows:
...
Signed-off-by: Simon Horman <redacted>
---
v4
* Use interrupts-extended rather than interrupt-parent + interrupts
  in /pmu_* and /timer nodes as seems to be preferred.
v3
* Add interrupt-parent property to /pmu_* and /timer nodes as
  it is no longer inherited from the parent node
v2
* Preserve alphabetical order of nodes present in root node.
I have applied this with Geert's review tag from v2.
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree