[QUERY] AMBA: PM domains when !CONFIG_PM

From: Sudeep Holla <hidden>
Date: 2016-06-16 11:19:13
Also in: linux-pm

Hi Ulf, Kevin,

I have a situation where we need to enable the power domain to access an
AMBA device. This is all fine with patches from Ulf and Marek in amba/bus.c

The problem is when we disable CONFIG_PM, dev_pm_domain_attach
returns -ENODEV irrespective of whether a DT node has a PM domain
in it or not. If dev_pm_domain_attach returns anything other than
-EPROBE_DEFER, we ignore the error and proceed to access the device
which will explode.

Basically, we need a way to prevent addition of that amba device if DT
node has PD specified but CONFIG_PM=n. Any thoughts ?

-- 
Regards,
Sudeep